background image

 

8

WARNING!

 TURN ALL POWER OFF TO THE DISPENSER AND PUMP AT 

THE BREAKER PRIOR TO PERFORMING ANY SERVICE.  Release any 
pressure in the piping, hoses, and nozzle prior to performing any service.  
Failure to comply with these warnings can result in explosion, fire, bodily injury, 
and possibly death. 

 

 

 
 
 
Cabinet Assembly 

(refer to page 9 for item # diagram)

 

 

Access to the internal components of the 902 Series Dispenser is gained by removing the 
metal cabinet cover (item 3).  To do this, pull the reset knob (item 16) out by grasping it and 
pulling it firmly away from the cabinet.  Next, remove the 3 large Phillips head screws from the 
sides and back of the cabinet assembly (item *).  The metal cabinet cover can now be 
removed from the cabinet base (item 1).  Use caution when lifting the metal cabinet off the 
base plate to minimize the possibility of scratching the clear plastic window.  

 

Counter Assembly 

(refer to page 11 for item # diagram)

 

 

For access to the counter assembly: 

 

1) 

Remove the two screws (item 19) to extract the counter mechanism. 

2) 

Reassemble by reversing this procedure. 

 

Meter Chamber Assembly 

(refer to page 11 for item # diagram)

 

 

The Meter Chamber Assembly consists of upper and lower chambers, a nutating disc, and 
four screws.   

 

1) 

To expose the meter chamber assembly, gear train and seal remove 4 screws (item 23). 

2) 

The meter chamber can be dislodged by removing 4 screws (item 21). 

 

Reassemble by reversing this procedure. 

 

 
 
 

  

 

 

 

Gear Train and Seal 

(refer to page 11 for item # diagram) 

 

To disassemble the gear train and seal: 

 

1) 

Remove two screws (item 20) and gear frame (item 8). 

2) 

Remove the gear cluster (item 16), washer (item 17), and shaft (item 15). 

3) 

Remove the drive gear (item 14) and washers (item 12) by rotating and pulling the drive 
gear. 

4) 

Remove the O-ring seal (item 13). 

 

  
 
 

 
 
 
 
 
 
 
 

IMPORTANT!

 If replacing any components of the meter chamber, the complete 

assembly must be replaced due to its precision method of construction.  This 
will assure a proper fit, and correct operation of the chamber.

 

IMPORTANT!

 

When reassembling seal, lubricate O-ring with oil or petroleum 

jelly and replace in cover. Place washer on drive gear shaft.  Carefully rotate 
and push shaft through O-ring and cover to prevent damage to O-ring.  Shaft 
must also be guided into pinion bevel (item 18) if counter has not been 
removed.  Replace remaining parts to complete assembly by reversing 
disassembly procedure.

Содержание Fill-Rite

Страница 1: ...ote Dispensing Cabinet 902V Series Cabinet Dispenser Models FR902R non UL gallon FR902LR non UL liter FR902RU UL cUL listed gallon FR902LRU UL cUL listed liter Owners Installation Operation and Safety Manual ...

Страница 2: ...nd it providing you the value that comes with superior performance user friendly design long service life and solid simple engineering Experience that gives you peace of mind Rest Easy It s Tuthill About This Manual From initial concept and design through its final production your Fill Rite dispenser is built to give you years of trouble free use To ensure it provides that service it is critical t...

Страница 3: ...be incorporated into the installation either as part of the pump or separately at the dispenser itself WARNING This product must not be used to transfer fluids into any type of aircraft WARNING This product is not suited for use with fluids intended for human consumption or fluids containing water WARNING To ensure safe and proper operation of your equipment it is critical to read and adhere to al...

Страница 4: ...to support the pump or the dispenser in any manner NOTE Dimensional drawings for installation purposes are located on pages 12 16 Electrical Installation CAUTION Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks Figure 1 WARNING Overall dispenser installation and electrical wiring should be performed ONLY by a li...

Страница 5: ...5 RED RED RED RED Connect Red and Black Wires to 110 VAC wire unless separate circuits are required 110 VAC ...

Страница 6: ...r and piping must always be filled with liquid and be free of air The meter portion of your dispenser should be calibrated per instructions in this manual prior to its use 1 Reset register to 0 DO NOT RESET WHILE IN OPERATION Damage will result 2 Remove nozzle from holder and turn the power on by lifting the switch handle 3 Dispenser is ready for use Insert nozzle into container to be filled and s...

Страница 7: ...low capacity Clogged meter chamber Clean meter chamber clean or replace screens and filters in piping Plugged filter Replace filter element Plugged pump Inspect and clean pump as necessary Meter body cracks Excess line pressure Install pressure relief valve so high pressure bleeds back to the tank Replace cracked meter body Nutating Disc Broken Sudden high pressure fluid hitting disc Avoid surge f...

Страница 8: ...mber Assembly refer to page 11 for item diagram The Meter Chamber Assembly consists of upper and lower chambers a nutating disc and four screws 1 To expose the meter chamber assembly gear train and seal remove 4 screws item 23 2 The meter chamber can be dislodged by removing 4 screws item 21 Reassemble by reversing this procedure Gear Train and Seal refer to page 11 for item diagram To disassemble...

Страница 9: ...rning for repairs Replacement Parts Information For repairs or routine maintenance Fill Rite offers the parts you need The following parts diagram and list covers all applicable parts for your Fill Rite product These parts can be obtained through any authorized Fill Rite dealer FR902RU Configuration FR902R Config Cabinet Screws ...

Страница 10: ...eries Meter Chamber and gear train components To assure proper operation on a solid mounting surface Fill Rite recommends installing the FR902 Cabinet Dispenser on the KIT902MB Mounting Bracket kit This mounting bracket is designed specifically for use with the FR902 series Cabinet Dispenser and features pre drilled openings located for plumbing wiring and fastening It also includes the necessary ...

Страница 11: ...arts Kit Description Contents 900KT 900 Series Meter Repair Kit 1 Pin Gear 2 Cluster Gear Liter or Gallon 3 Drive Gear Liter or Gallon 4 Bevel Pin 5Driver pin gear 6 Gear Frame 7 Chamber Assembly 8 Required O rings 9 Required Fasteners ...

Страница 12: ...12 Cabinet Exterior Dimensions ...

Страница 13: ...13 Optional Mounting Platform Dimensions ...

Страница 14: ...14 Cabinet to Platform Orientation ...

Страница 15: ...15 Typical Above Ground Tank Installation ...

Страница 16: ... Buyer against the Manufacturer for breach of warranty IN NO EVENT SHALL THE MANUFACTURER S LIABILITY FOR ANY CLAIM FOR DAMAGES ARISING OUT OF THE MANUFACTURE SALE DELIVERY OR USE OF THE GOODS EXCEED THE PURCHASE PRICE The foregoing warranties will not extend to goods subject to misuse neglect accident improper installation or maintenance or have been repaired by anyone other than the Manufacturer...

Отзывы: