IMPORTANT!

  When the meter is in the “Deep Sleep” mode, dispensing fluid will 

NOT

 turn the meter on.  The meter will not display or accumulate any fluid that is 

dispensed while in “Deep Sleep” mode. 

•  Pressing any button will turn the meter

 

   on when in deep sleep mode (fluid flow

 

   will not turn the unit on or cause it to exit

 

   deep sleep mode).

•  The last count and selected totalizer is

 

   retained and displayed when the meter

 

   is turned on.

•  Pressing and releasing the TOTAL

 

   button will switch between the resettable

 

   and non-resettable totalizers. (The “R”

 

   icon will be displayed when the

 

   resettable total is displayed).

•  Pressing and holding the RESET button

 

   for 2 seconds will reset the counter.

•  Pressing and holding the RESET button

 

   and TOTAL buttons for 2 seconds will

 

   reset the totalizer. The resettable totalizer must be active in order to reset it.

•  Pressing and holding the RESET button and CAL buttons for 2 seconds will display the  

   software version for 2 seconds and then perform a segment check for 3 seconds, and 

   then restore the display.

•  Pressing and holding the CAL button for 5 seconds will place the meter into a deep sleep  

   mode.

IMPORTANT! 

 “Deep Sleep” mode is designed to maintain a status of operational 

readiness while offering battery conservation.  The meter should be placed in this 

mode under the following circumstances: 
•  Flushing the unit so the dispensed volume is not counted.

•  Traveling over rough surfaces (off-road); fluid in the metering chamber will be   

   counted if fluid is being jostled.

•  Extending battery life; the meter can be placed in deep sleep mode repeatedly 

   with no adverse effect on battery life.  

•  After 30 seconds of inactivity, the display will blank to conserve battery power.

•  If the meter is connected to the external power source, the display will not blank unless  

   forced into deep sleep mode.

•  If external power is removed, the meter will automatically switch to battery only operation 

   and vice-versa.

•  The counter and resettable totalizer 2 can be reset even if fluid flow is detected.  The  

   meter will continue counting during the 2 second RESET button press, reset to 0, and  

   resume counting.

Low Battery Warning 

The digital display includes a “Low Battery” 

warning indicator.  When the batteries 

reaches a level low enough to require 

replacement, the display will show “BAT” 

as a reminder to change them.  Replace 

batteries when indicated per procedure on 

page 8.

6

Содержание Fill-Rite 900CDP

Страница 1: ...s 900DP High Flow Models with Intrinsically Safe Barrier 900CDP 900CDP1 5 900CDPBSPT 900CDP1 5BPST Models without Intrinsically Safe Barrier 900CDPX 900CDPX1 5 900CDPXBSPT 900CDPX1 5BSPT Tuthill Corporation 8825 Aviation Drive Fort Wayne IN 46809 260 747 7524 www fillrite com ...

Страница 2: ...nd solid simple engineering Experience that gives you peace of mind and passion for building real things that make a real difference About This Manual From initial concept and design through its final production your Fill Rite meter is built to give you years of trouble free use To insure it provides that service it is critical that you read this entire manual prior to attempting to install or ope...

Страница 3: ... valve otherwise the meter may rupture WARNING This product should not be used to transfer any type of aviation fuel WARNING This product is not suited for use with fluids intended for human or animal consumption or fluids containing water Nickel plated meters are approved for use with non potable water antifreeze certain agricultural chemicals and other specialized water applications Installation...

Страница 4: ...h a known volume using the desired fluid 3 Enter the amount of fluid dispensed Prior to calibration the unit must be placed in calibration mode Press and hold the TOTAL and CAL buttons for 5 seconds to enter Calibration Mode IMPORTANT When calibrating the totalizers will not increase in value 1 The unit will default to the last unit of measure used 2 Press and release the TOTAL button to toggle th...

Страница 5: ...essed for less than 2 seconds the process will roll back to the left most digit but retain the current value This allows the user to edit an incorrect value 19 An error check for gross calibration errors 15 will be performed unless USER units are selected If an error is detected the meter will display Err0 until a button is pressed and the calibration process is aborted 20 If the meter is left unt...

Страница 6: ...l place the meter into a deep sleep mode IMPORTANT Deep Sleep mode is designed to maintain a status of operational readiness while offering battery conservation The meter should be placed in this mode under the following circumstances Flushing the unit so the dispensed volume is not counted Traveling over rough surfaces off road fluid in the metering chamber will be counted if fluid is being jostl...

Страница 7: ...ring components as necessary Low flow capacity Clogged meter chamber Clean meter chamber clean or replace screens and filters in piping Meter body cracks Excess line pressure Install pressure relief valve to allow high pressure to bleed back to the tank Replace meter Nutating Disc Broken Sudden high pressure fluid hitting disc Avoid surge flows by installing a shut off valve on outlet of meter ins...

Страница 8: ...nutating disc and four screws figure 2 The meter chamber can be dislodged by removing 4 screws Reassemble by reversing this procedure Figure 2 IMPORTANT If replacing any components of the meter chamber complete assembly must be replaced due to its precision method of construction This will assure a proper fit and correct operation of the chamber Repair Meters needing repairs should be taken to an ...

Страница 9: ...at www fillrite com WARNING Substitution of parts may impair intrinsic safety Models with Intrinsically Safe Barrier 900CDP 900CDP1 5 900CDPBSPT 900CDP1 5BPST Models without Intrinsically Safe Barrier 900CDPX 900CDPX1 5 900CDPXBSPT 900CDPX1 5BSPT 900 Series Digital Meter Replacement Parts Kits Kit Number Description Qty KIT900DKY KIT900DPBA 1 2 3 4 5 Required Seal 3 6 1 1 1 Required Fasteners Magn...

Страница 10: ...Digital Meter featuring two different power sources It is critical that the meter be installed and wired correctly to ensure correct safe operation WARNING Electrical wiring should be performed ONLY by a licensed electrician in compliance with local state and national electrical codes NEC ANSI NFPA 70 NFPA30 and NFPA 30A in US installations for example as appropriate to the intended use of the met...

Страница 11: ...r DC external power MUST be routed through the Intrinsically Safe Barrier any time the meter is installed in an explosive atmosphere External power sources MUST be within the rated parameters of the intrinsically Safe Barrier and meter External AC Power External AC power CANNOT be applied directly to the 900DP meter It must be routed through the Intrinsically Safe Barrier regardless of meter insta...

Страница 12: ...nning installation WARNING Substitution of components will impair intrinsic safety WARNING To prevent ignition of combustible or flammable atmosphere disconnect power before servicing WARNING To prevent ignition of flammable or combustible atmosphere do not use a volt meter or similar powered tools during live maintenance WARNING Intrinsically Safe Barrier must be housed in a environmentally safe ...

Страница 13: ...lifies wiring and improves current sink and voltage quality The pulser in the meter is designed to function directly with Fuel Management Systems using a current sink output with a maximum load of 20mA The Series 900DP Digital Meter can be wired directly to an external DC power source that operates within the meters parameters 7 5 28 VDC 2A Any external power sources should be clean DC from a dedi...

Страница 14: ...llons 1 special unit of measure option Counter 4 digit resettable counter 01 9999 units Totalizers 7 digit non resettable Master totalizer 7 digit resettable secondary Mounting Options Can be installed for vertical or horizontal mounting by rotating display accordingly Power Supply 2 AA batteries Dura cell MN1500 MX 1500 or Energizer E91 Alkaline batteries only optional external power through Intr...

Страница 15: ...are installed WARNING CONDITIONS FOR SAFE USE The Remote Reed Switch Assembly Part No SA000048 005 is provided with a non metallic housing Care must be taken to avoid ignition hazards due to potential electrostatic charging hazard Warranty Information Your quality Tuthill Fill Rite product carries a full manufacturers limited warranty For terms and conditions of that warranty please visit www fill...

Страница 16: ... 5th ed UL 60079 11 5th ed CAN CSA C22 2 No 157 92 Entity Parameters The Series 900DP meter has the following entity parameters Ui 13 65 V Ii 0 319 A Pi 1 343 W Li 0 mH Ci 10 8uF WARNING Substitution of components will impair intrinsic safety WARNING To prevent ignition of combustible or flammable atmosphere disconnect power before servicing WARNING To prevent ignition of flammable or combustible ...

Отзывы: