Safety Information

WARNING!

  To insure safe and proper operation of your equipment, it is critical 

to read and adhere to all of the following safety warnings and precautions.  

Improper installation or use of this product can cause serious bodily injury or 

death!

• 

NEVER smoke near the meter, or use the meter near open flames when 

metering a flammable liquid!  Fire can result!

• 

A Fill-Rite Filter should be used on the meter outlet to insure no foreign 

material is transferred to the fuel tank.

• 

Threaded pipe joints and connections should be sealed with the appropriate 

sealant or sealant tape to minimize the possibility of leaks.

• 

Storage tanks should be securely anchored to prevent shifting or tipping 

when full or empty.

• 

To minimize static electricity build up, use only static wire conductive hose 

when metering flammable fluids, and keep the fill nozzle in contact with the 

container being filled during the filling process.

• 

DO NOT exceed 50 psi/ 3.5 BARS line pressure.

• 

DO NOT install additional foot valve or check valve without a pressure relief 

valve; otherwise the meter may rupture. 

WARNING! 

 This product should not be used to transfer any type of aviation fuel.

WARNING! 

 This product is not suited for use with fluids intended for human or 

animal consumption or fluids containing water.  Nickel plated meters are approved 

for use with non-potable water, antifreeze, certain agricultural chemicals, and 

other specialized water applications.  

 

Installation 

Meters are furnished for horizontal piping; left to 

right flow.  The display can be rotated to any of four 

positions for horizontal or vertical piping and for 

either direction of flow.   
1.  Determine direction for fluid to flow.

2. 

Install meter observing directional arrow on 

casting on back of meter (circled).  Liquid 

MUST flow in the direction of the arrow for 

proper operation.

3.  Once the meter is plumbed into place, 

remove four screws (circled) on corners of 

meter face (Torx T25 bit required).

4. 

Rotate meter face assembly to desired 

orientation.

5. 

Replace four screws.

6. 

Complete installation by making sure the 

joints are properly sealed and meter is 

positioned for easy viewing and use.

CAUTION! 

 Threaded pipe joints and connections should be sealed with the 

appropriate sealant or sealant tape to minimize the possibility of leaks.

 

3

Flow 

Direction

Содержание Fill-Rite 900CDP

Страница 1: ...s 900DP High Flow Models with Intrinsically Safe Barrier 900CDP 900CDP1 5 900CDPBSPT 900CDP1 5BPST Models without Intrinsically Safe Barrier 900CDPX 900CDPX1 5 900CDPXBSPT 900CDPX1 5BSPT Tuthill Corporation 8825 Aviation Drive Fort Wayne IN 46809 260 747 7524 www fillrite com ...

Страница 2: ...nd solid simple engineering Experience that gives you peace of mind and passion for building real things that make a real difference About This Manual From initial concept and design through its final production your Fill Rite meter is built to give you years of trouble free use To insure it provides that service it is critical that you read this entire manual prior to attempting to install or ope...

Страница 3: ... valve otherwise the meter may rupture WARNING This product should not be used to transfer any type of aviation fuel WARNING This product is not suited for use with fluids intended for human or animal consumption or fluids containing water Nickel plated meters are approved for use with non potable water antifreeze certain agricultural chemicals and other specialized water applications Installation...

Страница 4: ...h a known volume using the desired fluid 3 Enter the amount of fluid dispensed Prior to calibration the unit must be placed in calibration mode Press and hold the TOTAL and CAL buttons for 5 seconds to enter Calibration Mode IMPORTANT When calibrating the totalizers will not increase in value 1 The unit will default to the last unit of measure used 2 Press and release the TOTAL button to toggle th...

Страница 5: ...essed for less than 2 seconds the process will roll back to the left most digit but retain the current value This allows the user to edit an incorrect value 19 An error check for gross calibration errors 15 will be performed unless USER units are selected If an error is detected the meter will display Err0 until a button is pressed and the calibration process is aborted 20 If the meter is left unt...

Страница 6: ...l place the meter into a deep sleep mode IMPORTANT Deep Sleep mode is designed to maintain a status of operational readiness while offering battery conservation The meter should be placed in this mode under the following circumstances Flushing the unit so the dispensed volume is not counted Traveling over rough surfaces off road fluid in the metering chamber will be counted if fluid is being jostl...

Страница 7: ...ring components as necessary Low flow capacity Clogged meter chamber Clean meter chamber clean or replace screens and filters in piping Meter body cracks Excess line pressure Install pressure relief valve to allow high pressure to bleed back to the tank Replace meter Nutating Disc Broken Sudden high pressure fluid hitting disc Avoid surge flows by installing a shut off valve on outlet of meter ins...

Страница 8: ...nutating disc and four screws figure 2 The meter chamber can be dislodged by removing 4 screws Reassemble by reversing this procedure Figure 2 IMPORTANT If replacing any components of the meter chamber complete assembly must be replaced due to its precision method of construction This will assure a proper fit and correct operation of the chamber Repair Meters needing repairs should be taken to an ...

Страница 9: ...at www fillrite com WARNING Substitution of parts may impair intrinsic safety Models with Intrinsically Safe Barrier 900CDP 900CDP1 5 900CDPBSPT 900CDP1 5BPST Models without Intrinsically Safe Barrier 900CDPX 900CDPX1 5 900CDPXBSPT 900CDPX1 5BSPT 900 Series Digital Meter Replacement Parts Kits Kit Number Description Qty KIT900DKY KIT900DPBA 1 2 3 4 5 Required Seal 3 6 1 1 1 Required Fasteners Magn...

Страница 10: ...Digital Meter featuring two different power sources It is critical that the meter be installed and wired correctly to ensure correct safe operation WARNING Electrical wiring should be performed ONLY by a licensed electrician in compliance with local state and national electrical codes NEC ANSI NFPA 70 NFPA30 and NFPA 30A in US installations for example as appropriate to the intended use of the met...

Страница 11: ...r DC external power MUST be routed through the Intrinsically Safe Barrier any time the meter is installed in an explosive atmosphere External power sources MUST be within the rated parameters of the intrinsically Safe Barrier and meter External AC Power External AC power CANNOT be applied directly to the 900DP meter It must be routed through the Intrinsically Safe Barrier regardless of meter insta...

Страница 12: ...nning installation WARNING Substitution of components will impair intrinsic safety WARNING To prevent ignition of combustible or flammable atmosphere disconnect power before servicing WARNING To prevent ignition of flammable or combustible atmosphere do not use a volt meter or similar powered tools during live maintenance WARNING Intrinsically Safe Barrier must be housed in a environmentally safe ...

Страница 13: ...lifies wiring and improves current sink and voltage quality The pulser in the meter is designed to function directly with Fuel Management Systems using a current sink output with a maximum load of 20mA The Series 900DP Digital Meter can be wired directly to an external DC power source that operates within the meters parameters 7 5 28 VDC 2A Any external power sources should be clean DC from a dedi...

Страница 14: ...llons 1 special unit of measure option Counter 4 digit resettable counter 01 9999 units Totalizers 7 digit non resettable Master totalizer 7 digit resettable secondary Mounting Options Can be installed for vertical or horizontal mounting by rotating display accordingly Power Supply 2 AA batteries Dura cell MN1500 MX 1500 or Energizer E91 Alkaline batteries only optional external power through Intr...

Страница 15: ...are installed WARNING CONDITIONS FOR SAFE USE The Remote Reed Switch Assembly Part No SA000048 005 is provided with a non metallic housing Care must be taken to avoid ignition hazards due to potential electrostatic charging hazard Warranty Information Your quality Tuthill Fill Rite product carries a full manufacturers limited warranty For terms and conditions of that warranty please visit www fill...

Страница 16: ... 5th ed UL 60079 11 5th ed CAN CSA C22 2 No 157 92 Entity Parameters The Series 900DP meter has the following entity parameters Ui 13 65 V Ii 0 319 A Pi 1 343 W Li 0 mH Ci 10 8uF WARNING Substitution of components will impair intrinsic safety WARNING To prevent ignition of combustible or flammable atmosphere disconnect power before servicing WARNING To prevent ignition of flammable or combustible ...

Отзывы: