Open suction and discharge gate valves.
•
Check for any leaks once gate valves are open. After completing these checks
the pump can be started.
CAUTION!
The pump should not be run dry. If after approximately 60 seconds there is no discharge of
liquid, stop the pump and investigate the possible cause.
Failure to comply with this could cause severe damage to internal seals, bushings and/or
metal parts.
Pump Performance Data
Size Capacity (gpm)
CC009
9
CC015 15
CC020 20
CC030 30
Based on pumping a fluid of 200
SSU viscosity at 50 psi and 1750
rpm.
Based on pumping a fluid of 100
SSU viscosity at 50 psi and 1750
rpm.
Size
1C
2C
3C
4C
5C
6C
Capacity (gpm)
3
8
17
36
61
84