8. If equipped, place retaining ring into lower retaining ring groove on shaft.
9. Place key into shaft keyway.
10. Lower inner magnet onto shaft until it bottoms onto retaining ring or shaft shoulder. Place
retaining ring into retaining ring groove on shaft
11. Place canister over inner magnet until the face of the canister flange bottoms onto the bracket.
To insure easy assembly of canister over o-ring, place a small amount of lubricating oil on
canister I.D. before assembly.
12. Position adapter securely on flat surface with the pump register end facing upward. Carefully
lower the pump/inner magnet sub-assembly into the adapter register.
13. Once the pump/inner magnet sub-assembly is in place, fasten it to the adapter with screws.
14. Place pump/inner magnet sub-assembly on a flat surface with the bearing housing register end
facing upward.
15. Place key into bearing housing shaft keyway.
16. Place bearing housing sub-assembly on a flat surface with shaft facing upward.
17. Carefully lower outer magnet onto shaft until outer magnet bottoms onto shaft shoulder.
18. Lock outer magnet onto shaft with set screws, installing the cone-pointed set screw first.
!
CAUTION
DO NOT PLACE HAND OR FINGERS BETWEEN THE BRACKET AND ADAPTER. The magnets
are extremely strong and will attract all metallic objects and can be the source of pinch points. Do
not wear watches or other metallic jewelry when working with magnets. See warning on page 2.
Use jack screws to assemble models 6300, 7200 & 8200 Series pumps. Jack screw kits are
available as part number 2CMG 558 for models 6302-4, 7202-4 & 8202-4 and part number 5CMG
558 for models 6305-6, 7205-6 & 8205-6.
Failure to follow proper procedures or use appropriate tools could result in injury to you or damage
to either personal property or the pump.
19. Install outer magnet assembly. Use jack screws to control the attraction of the inner and outer
magnets:
a. Place (3) guide studs into adapter through the bracket screw clearance holes and hand-
tighten.
b. Screw (1) jack screw into bearing housing until it extends to the end of the outer magnet.
c. Slowly unscrew jack screw from bearing housing. This will lower sub-assembly into
adapter register.
Содержание 6000
Страница 28: ...Service Manual 67 Page 28 of 36 Figure 3 Typical 6110 Series Pump ...
Страница 29: ...Service Manual 67 Page 29 of 36 Figure 4 Typical 7110 Series Pump ...
Страница 30: ...Service Manual 67 Page 30 of 36 Figure 5 Typical 6200 Series Pump ...
Страница 31: ...Service Manual 67 Page 31 of 36 Figure 6 Typical 6210 Series Pump ...
Страница 32: ...Service Manual 67 Page 32 of 36 Figure 7 Typical 6300 7200 8200 Series Pump ...
Страница 33: ...Service Manual 67 Page 33 of 36 Figure 8 Typical 6310 7210 8210 Series Pump ...
Страница 36: ...Service Manual 67 Page 36 of 36 Notes 7 00 ...