SYMPTOM

REMEDIES

THE GATE OPENS OK BUT AFTER CLOSING, IT REOPENS.

1. EXCESSIVE CLOSING PRESSURE.  IF THE GATE IS OVER ROTATING 

INTO A FIXED STOP, LOOSEN BOTTOM COLLAR AND READJUST GATE 
POSITION. (SEE PAGE 16)

2. THE AUTO-REVERSE SENSITIVITY IS TOO HIGH. READJUST 

SENSITIVITY. (SEE PAGE 16)

3. POWER BOLT LOCK MAY BE MISALIGNED. ADJUST ACCORDINGLY.

THE GATE MOVES A FEW FEET, BUT THEN STOPS AND/OR REVERSES.

1. THE AUTO-REVERSE SENSITIVITY IS TOO HIGH. READJUST 

SENSITIVITY. (SEE PAGE 16)

2. BATTERY VOLTAGE MAY BE TOO LOW.  MAKE SURE CHARGER AND/OR 

SOLAR PANEL ARE DELIVERING CURRENT.

THE GATE WILL NOT OPEN USING THE KEYFOB OR KEYPAD 
TRANSMITTERS.

1. CHECK SWITCH LOCATED ON BOTTOM OF CONTROL BOX, TO ENSURE 

IT IS IN THE “ON” POSITION.

2. CODE SWITCHES IN THE TRANSMITTERS DO NOT MATCH THE CODE 

SWITCHES IN THE RECEIVER. RESET THE CODE SWITCHES TO MATCH. 
(SEE KEYCHAIN TRANSMITTER INSTRUCTIONS.)

3. LOW OR DEAD BATTERY IN THE TRANSMITTER. REPLACE BATTERY.
4. FUSE BLOWN ON CIRCUIT BOARD. REPLACE FUSE. IF FUSES 

CONTINUE TO BLOW, CONTACT TURNSTYLE TECHNICAL SUPPORT 

(800-548-2212)

.

5. LOOSE WIRE. CHECK FOR LOOSE AND/OR UNATTACHED WIRES.
6. OPERATOR BATTERY LOW VOLTAGE. CHECK TRANSFORMER AND/OR 

SOLAR PANEL WIRING (PAGE 15). REPLACE BATTERY IF NECESSARY.

7. DEFECTIVE RECEIVER. REPLACE RECEIVER. 

IF YOU DETERMINE THE SYSTEM CANNOT BE RESTORED 
IMMEDIATELY, LOOSEN THE BOTTOM COLLAR ON THE OPERATOR, 
MAKING YOUR GATE MANUAL.

THE KEYFOB TRANSMITTER WORKS ONLY AT A SHORT DISTANCE.

1. TRANSMITTER BATTERY LOW. REPLACE BATTERY.
2. RECEPTION IS BEING BLOCKED. AN EXTERNAL ANTENNA MAY BE 

NECESSARY.

ONLY ONE GATE WILL OPERATE (DUAL GATES).

CHECK THE CRCUIT BOARD. IF YOU HAVE DUAL GATES, THERE SHOULD 
BE TWO WIRES ATTACHED TO THE WIRING TERMINAL MARKED “GATE1” 
AND TWO WIRES ATTACHED TO THE TERMINAL MARKED “GATE2.” IF NOT, 
REATTACH THE WIRES.

AUDIBLE ALARM SOUNDING.

RESET ON/OFF SWITCH. CHECK GATES FOR OBSTRUCTIONS.  IF THE 
ALARM CONTINUES, TURN OFF SWITCH FOR 5 MINUTES AND THEN 
TURN BACK ON. 

(THE AUDIBLE ALARM IS A SAFETY DEVICE AND 

SHOULD NEVER BE DISCONNECTED).

THE GATE OPENS BUT THEN CLOSES WITHIN A FEW SECONDS.

THE AUTO-CLOSE FEATURE MAY BE ACTIVATED. SEE PAGE 17 TO 
DEACTIVATE OR CHANGE THE DELAY TIME ON THE AUTO-CLOSE 
FEATURE.

THE POWER BOLT LOCK WILL NOT OPERATE.

1. CHECK THE WIRING. BOTH WIRES FROM THE POWER BOLT LOCK 

SHOULD BE WIRED INTO THE CIRCUIT BOARD AT TERMINAL “LOCK.”

2. CHECK THE “AUTO-CLOSE” SWITCHES ON THE CIRCUIT BOARD. THE 

LOCK WILL NOT WORK UNLESS SWITCH 1 IS “UP.” (SEE PAGE 17)

THE POWER BOLT LOCK CLOSES WHEN IT SHOULD OPEN AND OPENS 
WHEN IT SHOULD CLOSE.

THE WIRES ARE INCORRECTLY CONNECTED AT THE CONTROL PANEL.  
AT THE TERMINAL MARKED “LOCK” REVERSE THE POSITION OF THE 
TWO WIRES.

GATE SQUEAKS WHEN OPENING OR CLOSING.

TOP PILLAR MOUNTING BRACKET MAY BE MISALIGNED. CHECK THE 
OPERATOR AND TOP BRACKET FOR PLUMB AND LEVEL. ADJUST IF 
NECESSARY. (SEE PAGE 8)

GATE IS OUT OF ALIGNMENT AFTER CLOSING.

BOTTOM MOUNTING BRACKET IS NOT TIGHT ENOUGH. REALIGN GATES 
AND TIGHTEN BOTTOM BRACKET COLLAR SUFFICIENTLY. (SEE PAGE 7)

TROUBLESHOOTING THE OPERATOR AND ACCESSORIES

Содержание Pillar Ground

Страница 1: ...WWW TURNSTYLEGATES COM Foreign Domestic Patents Issued Pending 1 800 548 2212 1 Instruction Manual The Armless Gate Opener The Power Is In The Post Steel Model Pillar Ground Mount Operators...

Страница 2: ...EDED FOR INSTALLATION 5 VI PRE INSTALLATION MEASUREMENTS 6 VII INSTALLATIONS 7 A Pillar Mount 7 B Ground Mount 10 VIII BRACKETS 12 IX ELECTRONICS 14 Control Panel 14 Wiring Terminal Functions 15 Wirin...

Страница 3: ...entrapment protection 1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving 2 An automatic closing device such as a timer loop sensor or...

Страница 4: ...four single family dwelling or a garage or parking area associated therewith Class II COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator or system intended for use in a commer...

Страница 5: ...nd Mount operates as a stand alone installation in which the Turnstyle operator is set in the ground Each system is available in both Manual and Automatic configurations If your gate s are to be integ...

Страница 6: ...WWW TURNSTYLEGATES COM Foreign Domestic Patents Issued Pending 1 800 548 2212 6 Turnstyle Pillar Mount GMS utilizing Gate Mounting Brackets Integrated Turnstyle Pillar Mount GMS...

Страница 7: ...2 Mounting your Turnstyle Operator a Place Turnstyle operator into the lower bracket Loosen or remove the collar clamp from the lower bracket using a 5 16 hex wrench to increase ease of placing the in...

Страница 8: ...pillar mount bracket onto pillar post Depending on the construction of your pillar post drill your pilot holes and securely attach the upper pillar mount bracket Make sure the bracket is securely atta...

Страница 9: ...e correct location of the opposite lower pillar mount bracket is determined return to page 7 and follow installation instructions from Step 1 b Level lower pillar mount bracket At this point you have...

Страница 10: ...the end of your fence section located on the highest ground elevation d Level Turnstyle operator and secure ground sleeve into ground Once the appropriate size hole has been prepared with the ground s...

Страница 11: ...erator Return to page 10 and follow Ground Mount installation instructions from Step 1 a Determine location of your Turnstyle Ground mount GMS through Step 1 c Prepare concrete and then proceed below...

Страница 12: ...wrench Note Unicorn brackets have two nuts one on either side of the gate frame which provide a measurement adjustment feature by tightening and or loosening the nuts in order to prevent gaps between...

Страница 13: ...drilled holes in the wood gate and tighten to secure your wood gate onto the Turnstyle gate operator Thru bolts can also be used Optional The holes can be drilled directly into the wood gate through...

Страница 14: ...Control Board b Sensitivity Adjustment Potentiometers small round white controls with adjusting screw heads located in the upper right quadrants of the Control Board c Fuses located on bottom left si...

Страница 15: ...ection if gate was closing EMER VEH Emergency Vehicle Opener Input for Emergency Vehicle Opener Activation will open the gate Continuous activation will prevent the gate from automatically closing EXI...

Страница 16: ...nd close the way you want However adjustment to the desired positioning is very simple First direct your attention to the collar at the bottom of the operator s On a pillar mount the collar is a part...

Страница 17: ...the Power Bolt Lock Opening Down Switch 6 will enable the Power Bolt Lock or Magnetic Lock as selected Note If after enabling the Auto Close feature you find the gates are automatically opening rathe...

Страница 18: ...ntil the power bolt lock is completely open The power bolt lock is wired into the terminal labeled LOCK Polarity is critical Before mounting your lock to your gates follow the below sequence to ensure...

Страница 19: ...OUR GATE MANUAL THE KEYFOB TRANSMITTER WORKS ONLY AT A SHORT DISTANCE 1 TRANSMITTER BATTERY LOW REPLACE BATTERY 2 RECEPTION IS BEING BLOCKED AN EXTERNAL ANTENNA MAY BE NECESSARY ONLY ONE GATE WILL OPE...

Страница 20: ...e manufacturer will pay standard ground freight on the return of repaired or replaced items in warranty TURNSTYLE AUTOMATIC GATE OPERATOR TURNSTYLE ENTERPRISES INC LIMITED WARRANTY Warranty V 2 1 V 2...

Отзывы: