![Turnstyle Pillar Ground Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/turnstyle/pillar-ground/pillar-ground_instruction-manual_1182256015.webp)
WWW.TURNSTYLEGATES.COM
Foreign & Domestic Patents Issued & Pending
!
1-800-548-2212
15
2.
Wiring Terminal Functions:
The 18 sets of wiring blocks are labeled in white lettering. The function of each
wiring block is described below:
Spare 12V
- These three printed circuit board (PCB) terminals provide access points for 12VDC power that may be required
to power peripheral accessories and/or safety devices. If none of these devices are included in your final installation, these
terminals will remain unused.
CAUTION - Do NOT connect ANY voltage source to any of these terminals. Doing so
will damage the circuit board and render your warranty void.
Solar/AC
- Input for Solar Panel or supplied AC power supply. The polarity of the inputs is non critical. The recommended
voltage is either 12VAC or 18VDC @ 1 amp.
*DO NOT USE CONVENTIONAL 110V.
BATTERY - Input for battery source. This DC voltage requires correct polarity. However, reverse polarity will not
damage the control panel. The positive
(Red)
wire should always be connected to the left-hand terminal marked (+)
and the negative (Black) wire connected to the right-hand terminal marked (-).
SWITCH
- System power switch. This input is used to power ‘off’ / ‘on’ and to ‘reset’ the system. Upon power up, all
previous states are reset and the system will always initialize to gate being fully closed and locked.
CSF (Contact Strip Front of Gate)
- Input for contact safety edge installed on front of gate. Activated input will prevent
gate from closing, and reverse the gate direction if gate was closing.
CSB (Contact Strip Back of Gate)
- Input for contact safety edge installed on back of gate. Activated input will prevent
gate from opening, and reverse the gate direction if gate was closing.
EMER. VEH. (Emergency Vehicle Opener)
- Input for Emergency Vehicle Opener. Activation will open the gate.
Continuous activation will prevent the gate from automatically closing.
EXIT DET. (Exit Detection)
- Input for devices to be used to only open the gate. Activated input will start the gate opening
procedure if gate was not moving. Input activations while gate is moving have no effect.
KEYPAD
- Input for wired keypad, or other fixed input device in sight of gate. Activation will Open/Stop/Close/Stop the gate
(repeated activations cycle through these 4). Activation will not stop the alarm.
STOP/NCI (NON-CONTACTING INPUT)
- Input for non-contacting safety sensors, such as an optical sensor, with a
normally open output. Activated input will stop gate instantly and return gate to fully open position.
ALARM
- Output for 12VDC high volume (100 dB minimum) alarm (included). If alarm is activated, clicking the on/off switch
will silence the alarm and reset the system.
LIGHT
- Output for 12V lighting. Lights turn on when gate is moving and remain on for approximately 30 seconds after
completion of the cycle. Do not exceed 40W of lighting.
LOCK
- Terminal points for lock motor(s) leads. Multiple locks may be employed.
MAG LOCK
- Terminal points for magnetic lock leads. The Magnetic Lock activates as soon as the gates complete their
close cycle. The gate opening cycle will not begin until the Magnetic Lock disengages. The Magnetic Lock is wired into the
terminal labeled “Mag Lock” Polarity is not crucial. Switches 5 and 6 must be open.
GATE 1
- Terminal points for gate motor leads. Polarity depends on desired swing of gate. Use this terminal with a single
mount gate.
GATE 2
- Terminal points for gate motor leads. Polarity depends on swing of gate. Use this terminal in addition to Gate 1
with dual mount gates.
d.
Mag locks are polarity sensitive. Switches 5 and 6 must be open.