background image

The charger has a storage and load program for your convenience. This feature can store up to IO battery datasets by 

number.  Each dataset  represent  your settings  for a  particular  set of batteries.  Datasets  can be  reloaded for charging  or 
discharging to save having to re-enter all the parameter values again by hand. 

Data save program 

PROGRAM SELECT 

pave... 

This screen displays the data save program. You can press ◄Dec & Start/Enter 

button for 3 seconds to enter this interface directly. 

In the first line, number  "oo"  refers to the target memory number the user wants 
to choose. !n the second line, the  "memoryO_"  refers to the character the user 
wants to input. Press Inc►/◄ Dec button to walk letters, and then press Start/Enter 
button to confirm the chosen letter and moves to the nest letter position, when you 
finish the character, press  Start/Enter button twice to confirm the character. You 
can  delete  a  wrong  chosen  letter  by  pressing  Batt  type/Stop  button.  Hold 
Start/Enter button for more than 3 seconds to save the currently displayed name. 
Hold Batt type/Stop button to exit without saving changes done. 

Storage number: 00 -09 

Storing all of the current data into the specified memory location. 

This screen displays the data load program. You can press Inc & Start/Enter button 

for 3 seconds to enter this interface directly. 

In the second line,  "memoryO"  refers to the source memory number the user 

wants to choose. Press Start/Enter for more than 3 seconds to start the process. 

tv1emory location number: 00 •09 

Load alt parameters values from the selected location. 

Note:  As for the  "LOAD SETTING"  program. You can load in any of the numbers you have saved in the  "SAVE 
SETTING"  from  "00-09"  , for example, when you finish the last setting of 

NiMH  FORMING CHG 

1.0Ah  7.2V (6S) 

then you save it as 01 in the saving settings, and in the load setting, when you set  "memory 01  and press  "Start" 

button to load, and then the interface will display the 

NiMH  FORMING CHG 

1.0Ah  7 

2V 

(6S) 

And use the current information directly. 

21 

Содержание REAKTOR

Страница 1: ...Charger Dl lcharger Please use these instructions for the 120 Duo version The programming and menus are the same the difference is the Duo has the ability to charge 2 batteries so has 2 screens and 2...

Страница 2: ...battery 16 Discharging a NiCd NiMH battery 16 Charge to Discharge Discharge to Charge cycle mode for a NiCd NiMH battery 16 NiCd NiMH forming charge 17 Pb lead acid battery program 18 Charging a Pb ba...

Страница 3: ...nd has a fully integrated cell balancer Internal temperature sensor and temperature controlled automatic cooling FAN controlsthe internal temperature and providesintelligentprotection When the interna...

Страница 4: ...easurement The charger can not only measure the internal resistance of the bauerypack and also can measure theper cell internal resistance only available for lithium battery Perfect protection The cha...

Страница 5: ...lor change or distortion Do not try to charge non rechargeable dry cells Do not exceed the battery manufacturer s suggested maximum charge rates Beware that the external case temperature of the charge...

Страница 6: ...Dl OWa X XA XX XV NiCd DISCHARGE X XA XX XV Pd CHAR G 1 X XA XX XV XS Pb DISCHARGE Dec XJ A XX XV XS Bal SpttdXXXXXX nc Li Ian ON Bal Trickle XXX Dec XXX NiC lSensitivity DeltaV XXm ll Safety timff XX...

Страница 7: ...display the output voltage is the idle voltage measured at the output tcrminals that is the voltage ofthe connected battery pack Pressing Start for 3 seconds to monitor the resistance again Per cell...

Страница 8: ...es If the Bal Spt Cd is set to Fast the CV termination current will be higher the charging time shorter and the per cell voltage lower When set to Slow the CV termination current will be lower the cha...

Страница 9: ...Dec Inc Range 20 80 C 68 176 F F 9 S x C 32 Charging time upper limit The charging process will stop immediately ifit exceeds the set value Range 1 999 min Capacity proll Ction The charging dischargin...

Страница 10: ...precision discharge process The process won t stop until the current reaches xx ofthe configured discharge current Reduce ON OFF Range 1 99 Termination voltage for LiFe Adjust LiFe s charge terminati...

Страница 11: ...arge current during the CV phase Any time the battery s balance lead is connected the charger will monitor and display the cell voltages The balancer is only active during a BALANCE charge not during...

Страница 12: ...CE CHG AUTO lie Dec Inc Ban type Start Enter stop 3 seconds Balance charging mode of Lithium battery The left side of the first line set the type of ba11ery UP0 Lilo or LiFe The value on the left side...

Страница 13: ...lay the General Status information Fast charging a Lithium battery The charger first charges with constant currem CC according to the user setting then constant voltage CV when the charging voltage re...

Страница 14: ...discharge the battery based on the configured target voltage and the measured initial voltage of the battery The nominal target storage voltage depends on the type of Lithium battery 3 7SV ce11 for Li...

Страница 15: ...to detect number won t lower than the number set by the user You should make sure that the BattXf Start Enter configured number and the actual number for the baneryare the same and then you can start...

Страница 16: ...scharging current during the process Press Start Enter to make the discharge current blink then press Inc to increase or press Dec 10 decrease the value and press Start Enter to confirm the alteration...

Страница 17: ...c indicate charging while o indicates discharging Press Inc button to display each cell s voltage and its past cycling current see thebalancevoltage information cyclinginfonnation andpress Dec button...

Страница 18: ...rrent 0 05 7A FinalvohJg 0 9 0V Discharge status Youcan stoptheprocessatanytime bypressingBatt type Stop Press Dec todisplay the General Status inf onnation Charge to Discharge Discharge to Charge cyc...

Страница 19: ...ss NiMHForming CHG t OAh 7 2V 6S The left side ofthe first lineshows the type ofbatter NiCd NiMH The value onthe left side ofsecond line sets the cell capacity and the value on the right side ofsecond...

Страница 20: ...2P l 24V Status display You can stop the charging process at any ttme by pressing Batt type Stop Press Decto display the General Status informat1on Note the charger can support PB lead ac1d foaming ch...

Страница 21: ...ay The top line show the drive current and oltage The second lineshows the output capacity mAh and in the lower right corner alternately displays the output power or total run time You can stop the te...

Страница 22: ...1um battery Measure Internal Resistance Batt type 1 Start Enter stop 3 seconds 1 21 24 19m0 4 18 26 19mQ Inc l Dec Battery Pack IR 125mQ Measure internal resistance You can press Start Enter for more...

Страница 23: ...a wrong chosen letter by pressing Batt type Stop button Hold Start Enter button for more than 3 seconds to save the currently displayed name Hold Batt type Stop button to exit without saving changes...

Страница 24: ...includes verifying the mternal state and the condition ofits electronics In the case ofany error being detected the screen displays the error cause and the charger generates 3 beeps If the error occur...

Страница 25: ...pack is too low Pleasecheck the cell voltages one by one The voltage ofone ofthe cells in the Lithium battery pack is too high Please check the cell voltages one by one ln Halance charge mode no batt...

Страница 26: ...will be required to present proof of purchase invoice or receipt This warranty does not cover the damage due to wear overloading incompetent handling or using of incorrect accessories This symbol mea...

Отзывы: