Appendix 2 

Interpreting EC Readings from Turf Grass 

When taking direct-insert EC readings in turf grass with the Field Scout meter, it is often helpful to con-vert 
the measurement to the equivalent Saturated Media Extract (SME) value. This conversion will vary for 
different soils. For sandy soils, the expression:  

SME = 2.7FS + 0.8  

provides a good approximation. FS 

refers to the reading taken by the Field Scout meter. This equation is the basis for table 1. Table 2 lists a 
variety of grass species and the range of EC values (converted to SME) they can tolerate. 
 

FS 

 

SME 

 

FS 

 

SME 

 

FS 

 

SME 

 

0.1  

1.1  

1.1  

3.8  

2.1  

6.5  

0.2  

1.3  

1.2  

4.0  

2.2  

6.7  

0.3  

1.6  

1.3  

4.3  

2.3  

7.0  

0.4  

1.9  

1.4  

4.6  

2.4  

7.3  

0.5  

2.2  

1.5  

4.9  

2.5  

7.6  

0.6  

2.4  

1.6  

5.1  

2.6  

7.8  

0.7  

2.7  

1.7  

5.4  

2.7  

8.1  

0.8  

3.0  

1.8  

5.7  

2.8  

8.4  

0.9  

3.2  

1.9  

5.9  

2.9  

8.6  

1.0  

3.5  

2.0  

6.2  

3.0  

8.9  

0.1  

1.1  

1.1  

3.8  

2.1  

6.5  

0.2  

1.3  

1.2  

4.0  

2.2  

6.7  

0.3  

1.6  

1.3  

4.3  

2.3  

7.0  

0.4  

1.9  

1.4  

4.6  

2.4  

7.3  

0.5  

2.2  

1.5  

4.9  

2.5  

7.6  

0.6  

2.4  

1.6  

5.1  

2.6  

7.8  

0.7  

2.7  

1.7  

5.4  

2.7  

8.1  

0.8  

3.0  

1.8  

5.7  

2.8  

8.4  

0.9  

3.2  

1.9  

5.9  

2.9  

8.6  

1.0  

3.5  

2.0  

6.2  

3.0  

8.9  

 

Table 1: Conversion from Field Scout direct readings (

FS

) to equivalent Saturated Media Extract (

SME

values.  

(

Reference 9:3

. PACE Turfgrass Research Institute. San Diego, CA) 

Appendix 3 

Preferred EC Values for Selected Turfgrasses

 

 

Sensitive 

<3 mS/cm 

Moderately 

Sensitive 

3 -6 mS/cm 

Moderately 

Tolerant 

6 -10 mS/cm 

Tolerant 

>10 mS/cm 

 

Annual Bluegrass 

Annual Ryegrass 

Bent cv. Seaside 

Alkaligrass 

Colonial Bluegrass 

Chewings Fescue 

Perennial Ryegrass 

Bermudagrass 

Kentucky Bluegrass 

Creeping Bentgrass 

Tall Fescue 

Seashore Paspalum 

Rough Bluegrass 

Hard Fescue 

Buffalograss 

St. Augustine grass 

Centipedegrass 

Bahiagrass 

Zoysiagrass 

 

 

Relative tolerance of turfgrasses to soil salinity measured by the SME Method (“Salinity in Turfgrass”, Harivandi M.A. 
Butler J.D., Lin w. 1992).  
Note: The values on this table refer to measurement of a saturated media extract (SME) . Use table 1 to convert from 
direct-insert readings to SME. 

Содержание ECM1-N

Страница 1: ...paration You can test different levels in the soil profile with the eight inch long probe You can also use the probe to fine tune your fertility program Measurement can be made directly in the soil wi...

Страница 2: ...Use this portable EC meter and probe to measure salinity directly in the soil without tedious soil sampling and preparation Turfgrass managers can monitor for high salt levels on golf course greens an...

Страница 3: ...s will allow a representative average to be computed Important Do not touch the sensor tip with your fingers The oils on the skin will affect the probe s measurement accuracy Meter Settings Accessing...

Страница 4: ...e upper display shows the current measured temperature reading based on the factory default calibration 5 Dip the tester into a solution of known temperature and allow time for the built in temperatur...

Страница 5: ...rior to measurement Prior to calibration the tip of the probe should be cleaned with alcohol The tester will retain one calibration value in each mode conductivity TDS salinity when the instrument is...

Страница 6: ...ments at different soil depths you can determine where the salts are concentrated in the soil profile Soil moisture content will significantly influence the measured EC value To ensure accurate measur...

Страница 7: ...if needed The sample should have the consistency of a paste with slightly more water than if the media was in a pot and fully irrigated Press On Off button to power up the meter Insert the probe tip...

Страница 8: ...ter of the meter opening Be sure that the small O ring sits at the base of the large plastic assembly 6 While holding the assembly in place hand tighten the nut to the strain relief 7 Connect and tigh...

Страница 9: ...resolution 0 1 C 0 1 F Temperature accuracy From 0 to 50 C 0 5 C 0 9 F 1 LSD from 50 to 60 C 1 0 C 1 8 F 1 LSD General Display Graphics Dot matrix 80 x 100 pixel Auto off 8 5 minutes from last key pre...

Страница 10: ...0 3 1 6 1 3 4 3 2 3 7 0 0 4 1 9 1 4 4 6 2 4 7 3 0 5 2 2 1 5 4 9 2 5 7 6 0 6 2 4 1 6 5 1 2 6 7 8 0 7 2 7 1 7 5 4 2 7 8 1 0 8 3 0 1 8 5 7 2 8 8 4 0 9 3 2 1 9 5 9 2 9 8 6 1 0 3 5 2 0 6 2 3 0 8 9 Table 1...

Страница 11: ...transportation prepaid to Turf Tec International after contacting Turf Tec International and receiving a return authorization number Please include a dated proof of purchase with your tool ANY IMPLIE...

Отзывы: