V2.0 | 2021/06
33
9.3
Setting via the pushbuttons
NOTE
The devices with a teach button are ready for teaching in up to 300 s after the power
supply is switched on. The teach button is then automatically locked. A new teach-in
operation is only possible after the power supply has been reset.
Selecting the output
Select switching output 1: Press and hold down pushbutton 1 for 2…7 s.
Select output 2: Press and hold down pushbutton 1 for 8…13 s.
Setting the switching point
Switching point
Out2
Out1
GND/T1 > 8 s
13 s
LED GN 2 × 1 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 1 Hz
Measure and save
Fail
LED GN/YE
1.5 s × 5 Hz
OK
LED GN
1.5 s × 5 Hz
GND/T1 > 2 s
7 s
LED GN 1 × 1 Hz
Normal operation
U
B
/T2 > 2 s
LED YE
1 × 8Hz
Cancel
Fig. 33: Setting the switching point
Select the switching output.
Position the object for the switching point.
Save the switching point: Press and hold down pushbutton 1 for 2…7 s.
a
The individual switching point has been taught successfully if the green LED flashes for
1.5 s at a frequency of 5 Hz.