V02.00 | 2018/11
9
3.3
General Safety Instructions
n
The device only meets the EMC requirements for industrial areas and is not suitable for use
in residential areas.
n
The device may only be assembled, installed, operated, parameterized and maintained by
professionally-trained personnel.
n
The device may only be used in accordance with applicable national and international regu-
lations, standards and laws.
n
Any extended stay within the area of radiation of UHF devices may be harmful to health.
Maintain a minimum distance from the actively radiating surface of the UHF read/write head:
Region
Max. permissible
total radiant output power
Safety distance
Europe, Russia, China
2 W ERP (according to ETSI)
0.24 m
USA, Canada, Mexico
30 dBm ERP
> 0.22 m
The minimum distances for other regions can be obtained from Turck on request.
n
The radiation of UHF devices may impair the operation of electrically controlled medical
equipment. Maintain an additional distance from active radiation sources up to the max-
imum transmission distance.