Setting

Setting and visualization with the Turck Radar Monitor

32

Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

9.3

Setting via IO-Link

The device can be parameterized within the technical specifications (see data sheet) via the IO-
Link communication interface – both offline, e.g. with the configuration tool as well as also on-
line via the controller. An overview of the different functions and properties that can be set and
used for IO-Link or SIO mode can be found in the chapter “Setting” and in the IO-Link para-
meter manual of the device. Detailed instructions on the parameterization of devices via the IO-
Link interface are provided in the IO-Link commissioning manual.

All the parameters can be changed in IO-Link mode via the controller during commissioning as
well as during operation. In SIO mode the device operates according to the last setting made in
IO-Link mode.

9.4

Setting and visualization with the Turck Radar Monitor

The device can be parameterized and tested via a Turck IO-Link master (e.g. TBEN-S2-4IOL). The
integrated web server of the IO-Link master offers access to all parameters of the sensor IODD.
For an overview of IO-Link parameters and descriptions see the IO-Link parameter manual. The
Turck Radar Monitor is also available for the visualization of process data.

A Turck IO-Link master is required for accessing the sensor parameters and the Turck Radar
Monitor. The following table shows the firmware version of the IO-Link master, which is re-
quired for using the Turck Radar Monitor:

IO-Link master

Firmware status

FEN20-4IOL

V1.1.0.0

TBEN-L4/5-8IOL

V3.3.0.0

TBEN-LL-8IOL

V1.1.0.0

TBEN-S2-4IOL

V3.4.0.0

Refer to the specific device instructions for use to obtain information on the Turck IO-Link mas-
ters.

„

Connect the IO-Link master to the power supply.

„

Connect the IO-Link master to a PC via the Ethernet interface.

„

Connect the radar sensor to an IO-Link port of the IO-Link master.

9.4.1

IO-Link master – opening the web server

„

To open the web server of the IO-Link master, enter the IP address in the address bar of a
web browser (default: 

http://192.168.1.254

).

A login is required on the IO-Link master in order to edit settings via the web server and to call
up the Turck Radar Sensor.

„

Enter the password in the Login field on the start page of the web server. The default
password is “password”.

„

Click 

Login

.

Содержание 100012722

Страница 1: ...Your Global Automation Partner Instructions for Use LRS510 Radar Level Sensors...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Страница 3: ...4 5 Functions and operating modes 10 4 5 1 Setting options 10 4 5 2 Normal operation run mode 10 4 5 3 Programming mode 10 4 5 4 Output functions switching output 10 4 5 5 Output functions analog outp...

Страница 4: ...Turck Radar Monitor 32 9 4 1 IO Link master opening the web server 32 9 4 2 Reading in IODD in the web server 33 9 4 3 Turck Radar Monitor overview 35 9 4 4 Turck Radar Monitor filtering signals 36 10...

Страница 5: ...of death or severe in jury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situation...

Страница 6: ...ng outputs H1 1 4 1 Electrical connection Connector Assignment 1 Standard assignment Number of contacts 4 4 contacts 8 8 contacts Alignment 1 Straight Design H1 M12 1 receptacle 2 2 Scope of delivery...

Страница 7: ...cribed in these instructions Any other use is not in accordance with the intended use Turck accepts no liability for any resulting damage 3 2 Obvious misuse n The devices are not safety components and...

Страница 8: ...or cable The process values are shown on the display The device functions can be set via touch pads or via IO Link Devices with the following output functions are available n LRS510 2UPN8 2 switching...

Страница 9: ...ith FCC CFR 47 Part 15 n 4 digit 2 color 12 segment display rotatable by 180 n Housing rotatable after mounting the process connection n Process connection G3 4 G1 2 NPT3 4 or NPT1 n NO NC programmabl...

Страница 10: ...evice detects the distance to the surface of the medium and shows the required switching or analog behavior according to the factory set or customer specific parameters The measured distance to the me...

Страница 11: ...In the defined measuring range between ASP analog start point and AEP analog end point the device supplies an analog current signal The following output configurations can be set n 4 20 mA factory set...

Страница 12: ...nsing functions are activated by default 4 6 Technical accessories Figure Type Description 132 144 3 32 32 C0 C1 C2 C3 24 17 9 28 X2 X1 P2 P1 4 6 TBEN S2 4IOL Compact multiprotocol I O module for Eth...

Страница 13: ...stalling LRS510 Install the sensor at the intended mounting location Observe blind zone smin in which no object detection is possible For optimum operation install the sensor in such a way that no for...

Страница 14: ...male connector of the sensor Connect the open end of the connection cable to the power supply and or processing units 6 1 Wiring diagrams 3 2 4 1 1 4 2 3 out 2 switch analog out 1 switch IO Link Fig...

Страница 15: ...V01 00 2021 07 15 7 Commissioning After connecting and switching on the power supply the device is automatically ready for operation...

Страница 16: ...h 20 40 Yellow flashing 4 Hz Signal strength 40 60 Yellow Signal strength 60 80 Green Signal strength 80 PCT Off Display of the selected unit Green Displayed in LOC Yellow Device locked Yellow flashin...

Страница 17: ...and behavior n Advanced settings Password setting Other setting options via IO Link Additional functions and properties can also be set via the IO Link interface n OUT1 output configuration for SIO m...

Страница 18: ...MODE and SET simultaneously for 3 s a When the LOC LED flashes Loc will appear on the display and then go out a LOC LED is yellow The sensor is automatically locked if the touchpads of the device are...

Страница 19: ...H3 rP3 FL3 ou4 option SP4 FH4 rP4 FL4 EF Current value Save value 3 s Hno Hnc Fno Fnc S M 3 s Hno Fnc Auto S M 4 20 rtio 3 s Hno Hnc Fno Fnc S M S 3 s Hno Hnc Fno Fnc S M 2 E M M S M S M S M S M S M S...

Страница 20: ...Current value years days hours E M S M S DiST DPCT LVL LPCT VOL VPCT S M 3 s E 3 s L m3 in3 ft3 gal S M mm m in ft S M 3 s E S S M OFF On M S E S M Current value Save value Current value Save value C...

Страница 21: ...1 07 21 9 2 4 VDMA menu overview VDMA menu main menu Process value 1 SP1 FH1 rP1 FL1 SP2 FH2 ASP rP2 FL2 AEP SP3 FH3 rP3 FL3 SP4 FH4 rP4 FL4 EF M S 2 M S M S M S M S M S M S M S M S M S E Fig 18 VDMA...

Страница 22: ...rent value Save value E S E E S E S E DiST DPCT LVL LPCT VOL VPCT Current value Save value S M S E E L m3 in3 ft3 GAL S M E Current value Save value mm m in Ft S M E Current value Save value M S M S M...

Страница 23: ...ode Chosen parameter Current value Save value Lower value Current value Higher value Acceleration Acceleration E E M Next parameter M M S 3 s M Gradually S Gradually S M Held Held E M S Fig 20 Setting...

Страница 24: ...or SET Certain values can be continuously changed by holding down MODE or SET Touch ENTER to save the modified value The stored value flashes twice and the next parameter is displayed 3 MOFF EMTY FuL...

Страница 25: ...ange values via SET Use MODE to navigate between the four digits of the password Use ENTER to store the new password 4 Save new PASS 0 F M M M E S Pos 1 flashes S Pos 2 flashes Pos 3 flashes Pos 4 fla...

Страница 26: ...status Default 50 of the detection range FL1 FL4 Lower switching point for window function ou1 ou4 Fno Fnc Lower switching point at which outputs 1 4 change their switching status Default 75 of the de...

Страница 27: ...u4 Function of output 4 Hno Hysteresis function NO NO contact Hnc Hysteresis function NC NC contact Fno Window function NO NO contact Fnc Window function NC NC contact EF Submenu for additional settin...

Страница 28: ...ory The lowest level is stored and can be displayed deleted hold down SET dSP1 dSP4 Switch delay of SP1 SP4 0 60 s in increments of 0 1 s 0 delay time not active Default 0 0 drP1 drP4 Switch delay of...

Страница 29: ...t Measured value and unit are displayed alternately measured value 4 s unit 1 s Off Unit is not displayed ON Unit is displayed cFH Virtual upper switching point Upper switching point at which the disp...

Страница 30: ...conical container Fig 27 Parameters spherical container Explanation Options Function GEOM Container shape CYLV Vertical cylinder CYLH Horizontal cylinder COnE Conical container SPHR Spherical contain...

Страница 31: ...oms at both ends DBot Diameter at the bottom edge of cone COnE Lower diameter of conical containers Default 0 0 hBot Bottom edge of cone COnE Position and height of bottom diameter of conical containe...

Страница 32: ...er of the IO Link master offers access to all parameters of the sensor IODD For an overview of IO Link parameters and descriptions see the IO Link parameter manual The Turck Radar Monitor is also avai...

Страница 33: ...01 00 2021 07 33 9 4 2 Reading in IODD in the web server Set the input port of the IO Link master as an IO Link port Open the IODD Configurator tab in the web server Fig 28 Web server IODD Configurato...

Страница 34: ...and visualization with the Turck Radar Monitor 34 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Load the specific device IODD in the web server via Load IODD Fig...

Страница 35: ...itor overview Each displayed peak represents an object detected by the sensor in the detection range The following points must be observed n Peaks with a blue bar max 10 value pairs consisting of dist...

Страница 36: ...een the foreground and background suppression is 0 1 mm Example If the foreground suppression is set to 1 m the background suppression must be 0 9 m or 1 1 m Minimum and maximum signal intensity filte...

Страница 37: ...irst check whether ambient interference is present If there is no ambient interference present check the connections of the device for faults If there are no faults there is a device malfunction In th...

Страница 38: ...return acceptance conditions when returning the device to Turck 12 1 Returning devices Returns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclose...

Страница 39: ...mm EIRP radiant power 10 dBm Opening angle 10 6 Repetition accuracy 2 mm Hysteresis 50 mm Electrical data Operating voltage 10 33 VDC Ripple 10 USS DC rated operational current 250 mA No load current...

Страница 40: ...port Smart sensor profile Mechanical data Design With display LRS Dimensions 127 1 38 mm Housing material Stainless steel plastic 1 4404 316L polyacrylamide 50 GF UL 94 V 0 Max tightening torque of ho...

Страница 41: ...ng angle 10 6 Repetition accuracy 2 mm Hysteresis 50 mm Electrical data Operating voltage 10 33 VDC Ripple 10 USS DC rated operational current 250 mA No load current 100 mA Residual current 0 1 mA Sho...

Страница 42: ...t Smart sensor profile Mechanical data Design With display LRS Dimensions 127 1 38 mm Housing material Stainless steel plastic 1 4404 316L polyacrylamide 50 GF UL 94 V 0 Max tightening torque of housi...

Страница 43: ...Repetition accuracy 2 mm Hysteresis 50 mm Electrical data Operating voltage 18 33 VDC Ripple 10 USS DC rated operational current 250 mA No load current 100 mA Residual current 0 1 mA Short circuit pro...

Страница 44: ...m cable length 20 m Profile support Smart sensor profile Mechanical data Design With display LRS Dimensions 127 1 38 mm Housing material Stainless steel plastic 1 4404 316L polyacrylamide 50 GF UL 94...

Страница 45: ...ay cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note This equipment has be...

Страница 46: ...S A S 11 rue de Courtalin Bat C Magny Le Hongre F 77703 MARNE LA VALLEE Cedex 4 www turckbanner fr Great Britain TURCK BANNER LIMITED Blenheim House Hurricane Way GB SS11 8YT Wickford Essex www turckb...

Страница 47: ...w turck ru Sweden Turck Sweden Office Fabriksstr ket 9 433 76 Jonsered www turck se Singapore TURCK BANNER Singapore Pte Ltd 25 International Business Park 04 75 77 West Wing German Centre 609916 Sing...

Страница 48: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100018911 2021 07 100018911...

Отзывы: