Placing
The unit is usually placed on the wall by a window, with the
extraction grille near the ceiling. This position makes the
most of the coanda effect, which circulates fresh air well into
the room. This gives the air longer to mix with the existing
air in the room, avoiding drafts.
Installation on wall/window
Reinforcement according to local building regulations is
required between the unit and window, which permits the
window to be retained by min. 3 frame fixing screws. The
hole in which the unit is fitted must be minimum 200 mm
wide and 1210 mm high to take the mounting frame.
The mounting frame supplied is
attached to the reinforcement and wall,
or between two reinforcements (if the
unit is placed between two windows)
using suitable screws.
Connect the unit to mains electricity,
and fit it in the mounting frame using
the M6 machine screws supplied. The
holes are located by the unit air filter
the lowest behind the filter cover.
Finish off by sealing around the unit.
Refer to the sealant compound
manufacturer's instructions.
Mounting screws