Intervene by taking the by-pass lever (FIG.37-REF.2) to the recirculation position (vertical) and check that the manometer
(FIG.37-REF.1) indicates a pressure of 0 (zero) bar.
Switch the machine off (take the mortar pump motor switch and master switch (FIG.32-REF.1) into position 0). Remove the
cause of the overload (mixture unsuitable or blocking of pipes or the gun) and then re-insert the safety device by acting on the
lever (FIG.39-REF.1).
1
FIG.39
If too much current is absorbed the motor protector intervenes inside the electric control board, which stops the machine.
The switches on the electric control board turn positioning themselves between 0 (zero) and I.
To insert the motor protector:
• Position the master switch (FIG.32-REF.1) in position 0 (zero). In the EMF version, before switching the machine off, put the
mortar pump motor (FIG.32-REF.2) and mixer (FIG.32-REF.3) switches at 0.
• ricercare la causa (cavo elettrico di sezione inadeguata, intasamento tubazioni, pistola e valvole; composizione impasto non
corretto) e provvedere al necessario rimedio.
• Per riavviare la macchina portare gli interruttori in posizione I.
7.8 MACHINE
SWITCH-OFF
When the last mixture has been pumped, which is better if it more fluid than normal, when the base of the mixing device can be
seen, stop the pump by closing the air flow cock, take the by-pass lever to the vertical position (FIG.40-REF.1) and check that
the manometer (FIG.40-REF.2) falls to 0 bar.
Stop the motor and place the mortar pump motor switch and the master switch (FIG.41-REF.1) in position 0.