3
Install Natural Gas(NG) Regulator and 12 Foot Hose
Connect the NG regulator to the inlet of gas manifold. (
See Fig. 4
)
Connect the swivel nut of the 12 ft. NG hose to the vertical fitting of the NG Regulator.
WHEN YOU FINISHED THIS STEP, PLEASE SKIP TO STEP 6.
NOTE: Make sure the 12 ft. NG hose stays away from sharp edges.
Gas Manifold
NG Regulator
Swivel Nut
of 12' Hose
Vertical fitting
16
Fig. 4
Install Regulator, Tank Tray Set and Liquid Propane(LP) Gas Tank
4
Pan Head Screw
3/16"x3/8"
Qty. 5
Part # S182G03061
Island Bottom Panel
Tank Tray Set
LP Gas Tank
Fig. 5
regulator hose
connector
5/8" UNF male
thread
clamp
(Not provided)
stainless steel flexible connec-
tor
(Not provided) must compy with the
Standard for connectors for Outdoor Gas
Appliances and Manufactured Homes,
ANSI Z21.75
•
CSA 6.27, and suitable for
outside installation.
The maximum length of the connection
shall be 6ft.(1.82m).
Note: Regarding the connector, for safety, we suggest use a stainless steel flexible connector. But, if using
semi-rigid tubing, do not use materials made of aluminum or aluminum alloy tubing. The connector should
be installed at the location visible when opening the door.
On the proper location, drill 2 holes on the island left side panel for installing the regulator hose
connector. Then install the regulator using 2 Pan Head Screws 3/16"x3/8" and tighten securely.
On the proper location, drill 3 holes on the island left bottom panel for installing the tank tray set. Then
install tank tray set using 3 Pan Head Screws 3/16"x3/8" and tighten securely.
Connect the stainless steel flexible connector to the manifold and regulator, then use a clamp to hold
the stainless steel flexible connector as shown for securing.
Place the LP gas tank into the tank tray set. Make sure the tank valve facing the right rear corner of
left island. Tighten the wing bolt to secure the LP gas tank. (
See Fig. 5
)
Connect the LP regulator onto the LP gas tank.
CAUTION:
There shall be a minimum clearance of 2 inches (50.8 mm) between the floor of the LP-gas cylinder
enclosure and the ground.