A. BEFORE YOU BEGIN
1. PRODUCT DESCRIPTION
The dehumidifier is used to remove excessive moisture from the air. The resulting
reduction in relative humidity protects buildings and their contents from the adverse
effects of excess humidity.
The environmentally friendly R290 is used as the refrigerant. R290 has no damaging
influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is
available worldwide. Because of its efficient energy properties, R290 is highly suitable as
a coolant for this application. Special precautions must be taken into consideration due
to the coolant's high flammability.
2. SYMBOLS FROM THE UNIT AND USER MANUA
L
This unit uses a flammable refrigerant. If refrigerant leaks and comes in contact
with fire or heating part, it will create harmful gas and there is risk of fire.
Read the USER MANUAL carefully before operation.
Further information is available in the USER MANUAL, SERVICE MANUAL, and the
like.
Service personnel are required to carefully read the USER MANUAL and SERVICE
MANUAL before operation.
THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
•
It is strongly recommended that installation and service should be performed by a qualified
technician or the service agency.
•
The unit is designed only for use with R-290(propane) gas as the designated refrigerant.
•
THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN SHOULD ATTEMPT TO SERVICE
•
Do not discharge the refrigerant into the atmosphere.
•
R-290 (propane) is flammable and heavier than air.
•
It collects first in low areas but can be circulated by the fans.
•
If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the
cause.
•
The propane gas used in the unit has no odor.
•
The lack of smell does not indicate a lack of escaped gas.