Turbines Incorporated
Cryogenic Flow Delivery System
CDS1000 Manual (Rev E)
CDS1000 Page
7
Installation
For best equipment performance, please follow these simple installation/operation/programming
instructions:
1.
Ensure that you have removed all the equipment from the shipping box:
Model #
Description
CDS1000
CDS1000-B
CDS1000 Main
Unit
√
√
900037 Power
Cable
√
900038 Signal
Cable
√
900039 Temperature
Cable
√
900040 Mounting
Bracket*
√
900206 Temperature
Sensor
√
900058 Knobs
(2)*
√
√
900062
PCO Cable **
900558 Pressure
Sensor
**
900506
Pressure Sensor Cable **
* Part of the
CDS1000
** Optional equipment
2.
Install any piping that was ordered. Temperature probe coupling should be down-stream
of the turbine.
3.
Mount the
CDS1000
at a height and angle ensuring ease of accessibility and visibility.
a.
Avoid installing under piping that defrosts often or near pumps that may spray
liquid.
b.
Use at least 4¼-20 bolts with lock washers and/or lock nuts.
4.
Install cables and connect to the rear panel.
Do not over tighten!
Connectors should be
hand tight.
a.
Route cables and tie wrap excess so that no rubbing of the cables will occur.
b.
Allow slack in the cables to allow the
CDS1000
to rotate for easy access to the
rear panel.
5.
Connect the power cable to the vehicle battery or other constant power source. It is not
recommended to connect the power to the lighting system of the truck/trailer.
a.
Power connections are polarity insensitive (+ and – may be reversed).
6.
Install the temperature probe:
a.
If using the PCO control: downstream of the pump
b.
If not using the PCO: Downstream of the turbine
c.
Connect the temperature probe wire to the top of the temperature probe. Tighten
cable lock nut hand tight.
7.
Install turbine meter and connect to signal cable or connect signal cable to existing meter.
Tighten cable lock nut hand tight.
8.
Press the
CDS1000
power button and observe LED lights are on or flashing. The main
LCD screen will indicate run mode.