General Operation 

 

The IBC70 Charger will supply "clean" nominal 13.6 VDC (Normal Mode) power from input voltages that range from 
90-130 VAC. 

The  IBC70  chargers  are  primarily  designed  for  use  with  batteries;  however,  the  output  of  the  IBC70  is  a  regulated, 
filtered DC voltage that can power sensitive electronics without the need for batteries or other filtering. 

The full rated 

capacity is available for loads, battery charging or both

. When functioning as a regulated battery charger the IBC70 

has a nominal voltage output of 13.6 VDC. The system was designed to sense voltage on the battery and automatically 
selects one of 4 operating modes (Boost, Normal, Storage and Equalization) to provide the correct charge level to the 
batteries. 

NOTE: 

AT A NORMAL INPUT VOLTAGE THE FULL LOAD RATED CAPACITY IS AVAILABLE. 
- AT AN INPUT VOLTAGE LESS THAN 105 VAC THE CHARGER MAY NOT SUPPLY IT’S 
FULL RATED OUTPUT CAPACITY. 

 

CAUTION: 

IT IS IMPORTANT THAT THE FLUID LEVEL OF ALL CONNECTED BATTERIES BE 
CHECKED ON A REGULAR BASIS (When possible). BATTERIES MAY “GAS” AND LOSE 
SOME FLUIDS WHEN CONTINUOUSLY CONNECTED TO ANY CHARGING SOURCE. 

 

 

4

 

Installation Instructions 

 

Horizontal  mounting  of  the  ICB70  is  recommended  although  it  can  be  mounted  in  any  position  that  provides 
unobstructed  ventilation  to  the  fan  and  vent  holes.  Secure  the  charger  firmly  to  the  mounting  surface  using  standard 
fasteners. 

Failure  to  provide  adequate  ventilation  to  the  charger  will  cause  it  to  cycle  on  and  off  as  it  responds  to  ambient 
conditions. 

The  charger  can  be  mounted  safely  up to  12ft from  the  batteries  using  AWG  2 cables  and  a  100A  CNL  fuse.  Using 
undersized  cables  may  overheat  the  charger  and  cause  a  premature  shutdown.  Make  sure  to  use  every  possible 
precaution when routing the cables thought sheet metal to prevent short circuit. 

 
CAUTION: 

THE IBC70 CHARGERS ARE NOT DESIGNED FOR ZERO CLEARANCE 
COMPARTMENTS. 

 

CAUTION: 

DO NOT EXCEED 50 IN / LB TORQUE ON THE OUTPUT TERMINALS. 

 

CAUTION: 

THE OUTPUT TERMINALS ARE RATED FOR AWG 2 COPPER WIRE MAX.  

 

CAUTION: 

THE  IBC70  CHARGERS  ARE  NOT  WEATHER  TIGHT  NOR  DESIGNED  FOR  WET   
LOCATION  MOUNTING.  THEY  MUST  BE  PROTECTED  FROM  DIRECT  CONTACT 
WITH WATER OR HIGH HUMIDITY. 

 

Содержание IBC70

Страница 1: ...Owner s guide IBC70 Install using Tundra CM Series installation kit Ask your retailer www tundrainternational com ...

Страница 2: ...ry Protection 3 1 4 Short Circuit Protection 3 1 5 Thermal Protection 3 1 6 Ignition Protection 3 1 7 Internal Component Cooling 3 1 8 Overvoltage Protection 3 2 General Information s 4 3 General Operation 5 4 Installation Instructions 5 5 Trouble shooting guide 6 6 Input Output Specifications 7 7 Limited One year warranty 8 ...

Страница 3: ... DAMAGED VEHICLE DAMAGE INJURY OR OTHER CONSEQUENCES 1 4 Short Circuit Protection The IBC70 senses within millionths of a second if the output terminals have been shorted If this condition should occur the charger first limits the current available Should the condition continue to exist the charger then shut down The IBC70 was designed to protect itself Once the short circuit has been corrected it...

Страница 4: ...OOST NORMAL STORAGE and EQUALIZE Each Mode is automatically selected by the Charge Controller and ensures a fast yet safe recharge for the batteries See chart below for details 14 4 Volts Boost Mode Rapidly brings the batteries up to 90 of full charge LED is steady ON 13 6 Volts Normal Mode Safely completes the charge LED blinks rapidly 2 sec 13 2 Volts Storage Mode Maintains charge with minimal g...

Страница 5: ...TERIES BE CHECKED ON A REGULAR BASIS When possible BATTERIES MAY GAS AND LOSE SOME FLUIDS WHEN CONTINUOUSLY CONNECTED TO ANY CHARGING SOURCE 4 Installation Instructions Horizontal mounting of the ICB70 is recommended although it can be mounted in any position that provides unobstructed ventilation to the fan and vent holes Secure the charger firmly to the mounting surface using standard fasteners ...

Страница 6: ... Reverse Polarity Replace Fuses with same type and rating Short Circuit Trace AC Circuits for possible fault Unit has shutdown due to overheating Check air flow Allow unit to cool Unit has shutdown due to over voltage Also see Item 5 below Check input voltage Charger will shut down if the input voltage exceeds 132 Volts AC Correct Input Voltage 2 External Fuses blown Reverse Battery Hook Up Correc...

Страница 7: ...7 IBC70 GD 0512 EN 6 Input Output Specifications Input 105 130 VAC 60 Hz 13 1A Output 13 6 VDC 70 Amps Dimensions 11 3 x 8 7 x 5 3 in Weight 5 8lbs ...

Страница 8: ...r other damages arising from the use misuse or operation of this product including without limitation damages resulting from loss of use cost of removal installation or troubleshooting of the customer s electrical systems Tundra International Inc will without charge repair or replace at its option a defective product upon delivery with all shipping and handling costs and full insurance paid for by...

Отзывы: