1  Features 

 

1.1.

 

Integrated Charge Controller 

The  IBC70  Chargers  have  undergone  tens  of  thousands  of  hours  of  strenuous  engineering  testing  to  insure  years  of 
trouble-free  operation. They  have  been  designed  and tested  to  provide  maintenance free  operation.  The  IBC70  is  the 
intelligent way to recharge your TRUCK batteries. The built-in microprocessor constantly monitors the batteries state 
of  charge  then  automatically  adjusts  the  output  voltage  to  provide  the  proper  charging  combination  of  voltage  & 
amperage for fast and safe recharges. 

1.2.

 

GFCI Protection 

The IBC70 has one of the LOWEST ground fault leakage. With this unit, the user can confidently use almost any AC 
outlets without being concerned about a ground fault interruption of the facilities power source. 

1.3.

 

Reverse Battery Protection 

If  a  battery  is  accidentally  hooked  up  backwards,  the  charger  will  be  protected.  Externally  mounted  ATC  type  fuses 
will blow when a battery is connected in reverse. Replace with same type and rating. 

 

CAUTION: 

IF  THE  REVERSE  BATTERY  PROTECTION  FUSES  ARE  BLOWN  DURING 
INSTALLATION,  CHECK  TO  SEE  THAT  THE  BATTERIES  HAVE  BEEN  CONNECTED 
PROPERLY BEFORE REPLACING THE FUSES. REPLACE THE FUSES ONLY WITH THE 
SAME  TYPE  AND  RATING  AS  THE  ORIGINAL  FUSES.  USING  OTHER  FUSES  COULD 
RESULT  IN  THE  CHARGER  BEING  DAMAGED,  VEHICLE  DAMAGE,  INJURY  OR 
OTHER CONSEQUENCES. 

 

1.4.

 

Short Circuit Protection 

The  IBC70  senses,  within  millionths  of  a  second,  if  the  output  terminals  have  been  shorted.  If  this  condition  should 
occur the charger first limits the current available. Should the condition continue to exist, the charger then shut down. 
The  IBC70  was  designed to  protect  itself.  Once  the  "short  circuit" has  been corrected, it  will  automatically  return  to 
normal operating conditions. 

1.5.

 

Thermal Protection 

If an over temperature condition should occur due to air flow obstruction or improper installation, the IBC70 senses the 
condition and decreases power output or shut down, until the unit returns to normal operating temperature. The charger 
will return to full output capacity as it cools down. 

1.6.

 

Ignition Protection 

All IBC70 Chargers are ignition protected, but must be kept away from flammable liquids. 

1.7.

 

Internal Component Cooling 

The  IBC70  Chargers  are  equipped  with  a  variable  speed  cooling  fan.  The  fan  will  only  run  at  the  speed  needed  to 
prevent the charger from overheating and shutting down. Running the fan at lower speeds where possible will reduce 
the audible noise generated by the fan while protecting the charger from excess heat. The location of the fan allows for 
the maximum cooling of both the case and components. 

1.8.

 

Overvoltage Protection 

If the Input Voltage exceeds a preset limit the charger will shutdown to prevent damages. The unit will return to normal 
operation when the voltage returns to normal.  
 

Содержание IBC70

Страница 1: ...Owner s guide IBC70 Install using Tundra CM Series installation kit Ask your retailer www tundrainternational com ...

Страница 2: ...ry Protection 3 1 4 Short Circuit Protection 3 1 5 Thermal Protection 3 1 6 Ignition Protection 3 1 7 Internal Component Cooling 3 1 8 Overvoltage Protection 3 2 General Information s 4 3 General Operation 5 4 Installation Instructions 5 5 Trouble shooting guide 6 6 Input Output Specifications 7 7 Limited One year warranty 8 ...

Страница 3: ... DAMAGED VEHICLE DAMAGE INJURY OR OTHER CONSEQUENCES 1 4 Short Circuit Protection The IBC70 senses within millionths of a second if the output terminals have been shorted If this condition should occur the charger first limits the current available Should the condition continue to exist the charger then shut down The IBC70 was designed to protect itself Once the short circuit has been corrected it...

Страница 4: ...OOST NORMAL STORAGE and EQUALIZE Each Mode is automatically selected by the Charge Controller and ensures a fast yet safe recharge for the batteries See chart below for details 14 4 Volts Boost Mode Rapidly brings the batteries up to 90 of full charge LED is steady ON 13 6 Volts Normal Mode Safely completes the charge LED blinks rapidly 2 sec 13 2 Volts Storage Mode Maintains charge with minimal g...

Страница 5: ...TERIES BE CHECKED ON A REGULAR BASIS When possible BATTERIES MAY GAS AND LOSE SOME FLUIDS WHEN CONTINUOUSLY CONNECTED TO ANY CHARGING SOURCE 4 Installation Instructions Horizontal mounting of the ICB70 is recommended although it can be mounted in any position that provides unobstructed ventilation to the fan and vent holes Secure the charger firmly to the mounting surface using standard fasteners ...

Страница 6: ... Reverse Polarity Replace Fuses with same type and rating Short Circuit Trace AC Circuits for possible fault Unit has shutdown due to overheating Check air flow Allow unit to cool Unit has shutdown due to over voltage Also see Item 5 below Check input voltage Charger will shut down if the input voltage exceeds 132 Volts AC Correct Input Voltage 2 External Fuses blown Reverse Battery Hook Up Correc...

Страница 7: ...7 IBC70 GD 0512 EN 6 Input Output Specifications Input 105 130 VAC 60 Hz 13 1A Output 13 6 VDC 70 Amps Dimensions 11 3 x 8 7 x 5 3 in Weight 5 8lbs ...

Страница 8: ...r other damages arising from the use misuse or operation of this product including without limitation damages resulting from loss of use cost of removal installation or troubleshooting of the customer s electrical systems Tundra International Inc will without charge repair or replace at its option a defective product upon delivery with all shipping and handling costs and full insurance paid for by...

Отзывы: