SAFETY PRECAUTIONS 

For safe operation of the weighing indicator, please follow these 
instructions:

 

● Calibration inspection and maintenance of the indicator are prohibited by non-pro-

fessional staff

 

● Please ensure that the indicator rests on a stable surface

 

● The indicator is a piece of static sensitive equipment; Please cut off power during 

electrical connections

 

● Touching the internal components by hand is prohibited

 

● DO NOT exceed the rated load limit of the unit

 

● DO NOT step on the unit

 

● DO NOT jump on the scale

 

● DO NOT use this product if any of the components are cracked

 

● DO NOT use for purposes other then weight taking

 

● To avoid damaging the battery do not keep charger plugged in once battery is fully 

charged

 

● Make sure the weight is not over the Max capacity as it could damage the load cell 

inside

 

● Material that has a static electric charge could influence the weighing. Discharge 

the static electricity of the samples, if possible. Another  
solution to the problem is to wipe both sides of the pan and the top of the case with 
an anti-static agent

Please take anti-static prevention measures

Any accumulated charge on the body of the human operator should be discharged first 
before opening the protective container with ESDS devices inside. The discharge can 
be accomplished by: 

 

● Putting a hand on a grounded surface or, ideally, by wearing a grounded Anti-static 

Wrist Strap and an Anti-static Mat

PREPARATION & SET UP

 

● Plug into a wall outlet to avoid interference with other wirings

 

● Turn on the balance while there is no load

 

● We suggest to warm-up the balance by powering on 5 minutes before use for  

accurate weighing

 

● Calibration may be required before weighing when the balance is initially installed 

or moved from a location

Содержание T902

Страница 1: ...www tufner com T902 INDICATOR USER S MANUAL...

Страница 2: ...1 Features 2 Technical Parameters 2 Power Supply 2 Display and Key Descriptions 3 Operating Instructions 4 Calibration 5 6 Indicator Parameter Settings 7 Helpful Definitions 8 Troubleshooting 8 Conne...

Страница 3: ...as it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the samples if possible Another solution to the pro...

Страница 4: ...l zero range 10 max capacity Manual zero range 2 max capacity Resolution Display Up to 1 15 000 Display Resolution Operation temperature 10 C 40 C Operation humidity 90 RH Storage temperature 40 C 70...

Страница 5: ...d Confirm ZERO Zero s the scale Tare s the scale Move Left UNITS Shifts between weighing units kg lb Move Down DISPLAY Meaning The scale is at zero The scale is stable Gross Shows you are in Gross wei...

Страница 6: ...table the indicator will Tare the scale and go into Net weighing mode when ZERO is pressed Hold There are three different hold functions you can choose the best option for you and set it the parameter...

Страница 7: ...unit is kg Press UNIT if you want to change the unit to lb Display will change to CAL lb Press HOLD to confirm your unit choice The display will most likely show FS 5 meaning the max capacity is 200kg...

Страница 8: ...ift and UNIT to change the calibration loading weight Then press HOLD to confirm The display will show CALon please follow the steps for FS values of 0 6 to complete calibration For FS values of 0 6 P...

Страница 9: ...ight 2 Manual hold Grabs the current weight 3 Auto hold Automatically holds data when stable Hold Time Ht 1 0 turn off hold time 1 15 second hold time 2 30 second hold time 3 45 second hold time 4 60...

Страница 10: ...rred in a communication channel example In the serial port context 9600 baud means that the serial port is capable of transferring a maximum of 9600 bits per second TROUBLESHOOTING Error Reason Soluti...

Страница 11: ...uick Disconnect DB9 Connection 9 pin Serial Connector The DB9 9 pin serial connector is used for different purposes depending on the indicator model Figure 4 shows the pin assignment on the DB9 9 pin...

Страница 12: ...2 port and the indicator will respond with the current data Communication Format is done using ASCII as shown below CR LF S 1 S 2 S 3 Data S 4 S1 weight status ST standstill US not standstill OL overl...

Страница 13: ...ECIFICATIONS CONTACT US Please e mail sales tufner com for any sales related questions Please e mail support tufner com for any support related questions Don t forget to visit our website at www tufne...

Отзывы: