Tuff Filbur FC-0125 Скачать руководство пользователя страница 6

 

                  

 

Hard Top Covers

 

 

1.

 

Hot and cold weather natural causes the material to expand and contract which may allow 
for gaps and/or inconsistencies between the cover and spa.  As long as the seal sits on the top 
edge of the spa any inconsistencies or small gaps around the edge of the cover will not affect 
the ability of the cover to retain heat and is purely aesthetic.  

2.

 

The high-grade resin from which the spas are constructed can be easily cleaned with a mild 
soap and water solution. 

3.

 

Any bolts/screws on the cover may need to be tightened on occasion, depending on use. 

 

 

Soft Top Covers

 

 

1.

 

Soft top covers are composed of a vinyl skin and high density foam insert. They have straps 
and two part clips which are attached to the spa. 

2.

 

The vinyl surface can be cared for with any mild household cleanser or products made for 
the care and maintenance of vinyl products. 

 

 

Cleaning Your Tuff Spa 

1.

 

The filter should be cleaned every 3-6 months with your garden hose. You may also choose 
to use a filter cleaner. Follow the directions provided with the cleaner.  

2.

 

If the shell gets dirty, you can simply use pressurized water to clean the majority of the dirt. 
In some cases you may need to use a mild soap and water solution. In this instance, you will 
need to thoroughly rinse the spa. If not, you will have an issue with bubbles. 

3.

 

Refill spa with fresh water to the recommended level. The water line should cover all the 
upper jets in the spa. If you encounter an air lock, refer to the “Relieving Air Locks” section 
above. 

Troubleshooting 

 

 

“LF” Error Code Fixes 

 

1.

 

The most common reason for this error code is a lack of water in the hot tub. The water line 
should be equal to the top of the highest jets (please refer to the “Filling Your Spa” section 
above). If it is not, add water to the spa to reach this level, then reset spa power. This will 
reset the memory and the error should be cleared. 

2.

 

The 2

nd

 most common reason for this error is an air lock during a fresh fill of water into the 

spa. Air locks are common when filling up a spa for the first time. Please see “Relieving Air 
Locks” section for tips on relieving air locks. If after the air lock is remedied you may still 
have a “LF” error on the topside. To reset the memory, simply reset spa power. This should 
clear the error code.  

3.

 

The 3

rd

 most common reason for this error code is a dirty filter or a clog in the line. Power 

off the spa, remove the filter, and reset power. If the issue persists, please contact your dealer 
for additional assistance. 
 
 

Содержание Filbur FC-0125

Страница 1: ...OWNER S REFERENCE GUIDE NORTH AMERICA ...

Страница 2: ...used for proper heating and filtration The pump will continue to run until reaching the set temperature The spa cord has a GFCI protection device If it repeatedly trips disconnect the plug from the receptacle until the fault has been identified and corrected by a spa technician 3 If an extension cord is used it must be as short as possible and at least 10 gauge for outdoor use Inferior cords may c...

Страница 3: ... is supplied with all 120v applications For 240v you will need a licensed electrician to run the necessary wiring unless proper wiring is already at site location 120v to 240v Conversion 1 Remove the necessary panel and locate the spa control pack 2 Remove the pack cover and locate the 120v electrical wiring Remove the 3 wire 120v cord and connect the 4 wire 240v hookup 50 amp breaker required 3 L...

Страница 4: ...s to repeatedly cycle between low and high speed on the topside controls If this does not fix the issue you will have to open the access panel that houses the pump Once the panel is removed locate the pump and you will see two large white nuts attached to the pump One is horizontal to the pump and the other is vertical Take a large pair of channel locks and loosen the horizontal nut with the pump ...

Страница 5: ...with your dealer or your local chemical supplier It is unhealthy to use your spa when the water is not in proper chemical balance Warning Do not use Calcium Hypochlorites or Trichlors Doing so may cause corrosion to your pump and possibly fade your spa surface This will not be covered under the warranty Minimum Weekly Maintenance 1 Test water for chlorine and pH 2 Adjust pH to 7 2 7 8 3 Adjust chl...

Страница 6: ...he dirt In some cases you may need to use a mild soap and water solution In this instance you will need to thoroughly rinse the spa If not you will have an issue with bubbles 3 Refill spa with fresh water to the recommended level The water line should cover all the upper jets in the spa If you encounter an air lock refer to the Relieving Air Locks section above Troubleshooting LF Error Code Fixes ...

Страница 7: ...e handle out and twist off the cap Attach a garden hose and carefully pull on the part where the hose and the drain assembly meet The assembly will pop out approximately opening the valve This is a gravity drain and as such will be slow so you may not see water draining immediately If you need to drain the spa more quickly you may rent buy a submersible pump 350 550 Models Remove the panel below t...

Страница 8: ...gh blood pressure circulatory system problems or diabetes should consult a physician before using a spa Persons using medication should consult a physician before using a spa Some medication may induce drowsiness while other medication may affect heart rate blood pressure and circulation Do not sit or stand on the edge of the spa or cover Hyperthermia occurs when the internal temperature of the bo...

Страница 9: ...S DESEASES SHOULD NOT USE A SPA OR HOT TUB AVERTISSEMENT LES PERSONNES ATTEINES DE MALADIES INFECTIEUSES NE DEVRAIENT PAS UTILISER UNE CUVE DE RELAXATION WARNING TO AVOID INJURY EXERCISE CARE WHEN ENTERING OR EXITING THE SPA OR HOT TUB AVERTISSEMENT POUR EVITER DES BLESSURES USER DE PRUDENCE EN ENTRANT DANS ONE CUVE DE RELAXATION ET E SORANT WARNING DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING THE...

Страница 10: ... L UTILISATION PROLONGEE D UNE CUVE DE RELAXATION PEUT ETRE DENGEREUSE POUR LA SANTE WARNING DO NOT PERMIT ELECTRIC APPLIANCES SUCH AS A LIGHT TELEPHONE RADIO OR TELEVISION WITHIN 1 5 M OF THIS SPA OR HOT TUB AVERTISSMENT NE PAS PLACER D APPAREIL ELECTRIQUE LUMINARE TELPHONE RADIO TELEVISEUR ETC A MOINS DE M DE CETTE COVE DE RELAXATION CAUTION MAINTAIN WATER CHEMISTRY IN ACCORDANCE WITH THE MANUFA...

Страница 11: ...ed spa and delivery and installation of the replacement or repaired spa will be the responsibility of the spa owner EXCEPTIONS TO WARRANTY 1 Any damage caused by negligent misuse improper installation improper water chemistry and or failure to follow instructions in the Owners Manual 2 Cartridge filter elements light bulbs stereos and all stereo components foam insulation and cover straps This war...