6-1: Instructions for use
These instructions do not replace regulations in force, which must also be followed.
•
Comply with permissible loads on the flooring and the structure.
•
Horizontal forces must not be over 30Kg.
•
Maximum wind allowed with stabilizers = 35Km/H
•
Anchor the scaffolding where winds are over 35 Km/h
Work area:
•
Do not install the unit close to any bare conductors under power.
•
Prohibit all access to scaffolding in zones accessible to the public.
•
Mark out the area of use if machinery or vehicles are liable to pass close by…
•
Check that there are no overhead obstacles in the area of movement
•
Provide for tracks when on soft ground.
The following is not allowed:
•
Using a jib. even a manual jib. placed on the outside of the
scaffolding.
•
Covering mobile scaffolding, even partially.
•
Increasing heights more than allowed.
•
Using components other than those supplied by the manufacturer.
•
Using scaffolding that has not been assembled vertically (tolerance: 1%).
•
Using scaffolding that has not been assembled as per the instructions contained in this manual.
•
Making a bridge between the scaffolding and a building or between two scaffolding units.
•
Leaning an access ladder against the scaffolding.
•
Jumping on floors.
•
Using planks for flooring.
•
Accessing the work floor from outside.
•
Adjusting wheels for increasing platform height. (At least one wheel must be fully withdrawn.)