TTL Luftschleieranlagen - Controller UBT2-E

9.  Basic - settings in Basic menu

Press the Mode key (PGM Mode display). Select Basic by using the multifunc-
tional rotary knob (the text colour will change from orange to black). Press the 

NQREWRFRQÀUPWKHVHOHFWLRQ

 

A menu will be displayed with the different setting options.

9.1 Day / date / time settings

Press the multifunctional rotary knob and turn it to select and change the rela-
ted data (24:00 hour notation).

9.2 Language settings

Press the multifunctional rotary knob and turn it to select and change the related data.  
If required, you can switch from GER to ENGNLDFRAITA oder PL.

9.3 Factory settings - defaults

Press the multifunctional rotary knob and turn it to select and change the related data. The original data is 

restored.

9.4 Start up

Press the multifunctional rotary knob and turn it to select and change the related data.  

After the air curtain has been switched on, the speed will switch to setting 1 during 3 seconds and, next, to set-

ting 5 for another 3 seconds automatically. Next, the system will operate based on the set fan setting (default 

setting: OFF).

9.5 Memory

Press the multifunctional rotary knob and turn it to select and change the related data.  
The memory function ensures that all set values are kept saved in case of power outage. (Default setting: me-

mory ON).

9.6 Overrun (turning-off delay)

Press the multifunctional rotary knob and turn it to select and change the related data.  

The turning-off delay at door contact operation can be set between 10 and 300 sec. (Default setting: turning-off 
delay 60 sec).

5XQWLPHÀOWHU

Press the multifunctional rotary knob and turn it to select and change the related data. The service life of the 

ÀOWHUFDQEHVHWEHWZHHQKRXUVGHIDXOWVHWWLQJKRXUV

Again press the MODE key to activate the changed basic setting.

AutoRT            21°C

  PGM Mode

Mo 01.01.12     11:55

Language        Ger

Werkseinst.     aus

Anlauf              aus

memory           aus

       060s

Nachlauf   

  950h

Filterzeit        

  Datum/Zeit

Содержание UBT2-E

Страница 1: ...UBT2 E Controller for TTL air curtain systems with electric heating User manual Translated English version...

Страница 2: ...contact control 9 7 3 Mode AutoTA automatic mode with anti cooling protection AKS 9 7 3 1 AutoTA automaticmode with AKS protection and door contact 9 7 4 Mode AutoRT automatic mode with room temperat...

Страница 3: ...placing of covers or inappropriate maintenance Do never open the covers during operation Do always cut off the power supply before opening and switch off repair switch Assembly disassembly start up re...

Страница 4: ...The top part is screwed with 4 screws with the basic plate The screws are accessible below the cover plugs at the case edges Illustration Fixing measures base plate illustration not true to scale Fixi...

Страница 5: ...Cover plastic gray front panel operating surface silver colored Dimensions l x h x d 122 0 x 70 0 x 35 0 mm Weight 136 g Conformity controller and internal connection board In accordance to Low Voltag...

Страница 6: ...utton select desired mode by central multifunctional wheel operating modes Manual Automatic modes AutoTK AutoTA AutoRT Automatic operating modes AutoTK AutoTA AutoRT Check or adjust of parameters Valu...

Страница 7: ...onelly groups Sutchlike units of a group will be controlled equal and operates at the same operating stage or power level By comparison to similar step switches TTL UBT E offers enlarged functions con...

Страница 8: ...ymbol Clock symbol timer OFF Clock symbol orange timer set in advance Press the MODE key again to activate the selected operational mode also see point 8 Default setting fan step 0 heating step 0 symb...

Страница 9: ...again to activate the selected operational mode If the temperature drops below the preselected value the system will switch to fan step 1 and heating step 1 WKH 6 GLVSOD ZLOO DVK UHG If the system us...

Страница 10: ...WXQJ XQG HL XQJVVWXIH NDQQ GLH HL XQJ GH QLHUW abgeschaltet werden Dies gestattet einen Betrieb der Luftschleieranlage ohne Heizung also beispielsweise zur T rabschirmung im Sommer gegen eindringende...

Страница 11: ...ed data After the air curtain has been switched on the speed will switch to setting 1 during 3 seconds and next to set ting 5 for another 3 seconds automatically Next the system will operate based on...

Страница 12: ...re different at most 20 m Room temperature sensor dimensions 70 x 70 x 27 mm 11 Messages OHDQ OWHU QG RI DGMXVWHG OWHU OLIH WLPH OHDQ OWHU XUJHQWO Filter can cleaned by a vac cleaner or can wipped cle...

Страница 13: ...13 Troubleshooting Error Display Possible cause Solution System is not working Display OFF 1RW HQDEOHG 6HQVRU GHIHFW No main power supply Not turned ON BMS DDC release fault Temperature sensor fault c...

Страница 14: ...ual Step Heating Timer Timer Set temperature AutoTK Step Heating Timer AutoTA Step Heating R Temp cooling protection temperature AutoRT Timer Timer Week switching clock Basic Start up Date time Langua...

Страница 15: ...by us If the product is altered in a manner not approved by us this declaration shall lose its validity Product designation Electronic controller for air curtain devices Model designation UBT2 E Appl...

Страница 16: ...er de Imprint User manual for controller TTL UBT 2E Translated English version 01 Manufacturer TTL Torluftschleier GmbH 1 Edition January 2019 1 500 printed at chloreene free paper By TTL Torluftschle...

Отзывы: