-2-
PRECAUTIONS DURING TEST OPERATION AND OPERATION
CAUTION
WARNING
Never try to operate the pump if
somebody is present in the pump
sump. If an electrical leakage
occurs, it can cause electrical
shock.
When changing power connection is
needed to correct the direction of
rotation, be sure to turn off the
power supply (earth leakage circuit
breaker, etc.), and perform the work
after making sure that the impeller
has stopped completely. Failure to
do so may lead to electrical
shock, short-circuit, or injury.
Never start the pump while it is
suspended, as the unit may jerk
and could lead to injury.
When inspecting the pump, be sure
to turn off the power supply (earth
leakage circuit breaker, etc.) so that
the pump may not start accidental-
ly. Failure to do so may lead to a
serious accident.
Do not operate the product under
any voltage other than described
on the nameplate with the voltage
tolerance limit within ±5%. If it is
operated with a generator, it is
strongly suggested not to operate
other equipment with the same
generator. Failure to observe
this caution may cause
malfunction and breakdown of
the product, which may lead to
electrical leakage or electrical
shock.
Do not touch the product with bare
hands during or immediate after
the operation, as the product may
become very hot during operation.
Failure to observe this caution
may lead to burn.
Do not use the product in a liquid
other than water. Use in oil, salt
water or organic solvents will
damage it, which may lead to
electrical leakage or electrical
shock.
Do not run the product dry or
operate it with its valve (sluice or
gate valve) closed, as doing so
will damage the product, which
may lead to electrical leakage or
electrical shock.
For water
only
Rated
Voltage
STOP
OFF
OFF
CAUTION
Do not scratch, fold, twist, make
alterations, or bundle the cable, or
use it as a lifting device. The cable
may be damaged, which may
cause electrical leakage, short-
circuit, electrical shock, or fire.
Be sure to provide a ground wire
securely. Do not connect the
ground wire to a gas pipe, water
pipe, lightening rod, or telephone
ground wire. Improper grounding
could cause electrical shock.
Do not use the cabtyre cable if it is
damaged. Connect every conductor
of the cabtyre cable securely to the
terminals. Failure to observe this
can lead to electrical shock,
short-circuit, or fire.
Install the discharge piping
securely so that no water leakage
may occur. Failure to do so may
result in damage to nearby
walls, floors, and other equip-
ment.
When the product needs to be
carried by hand, decide the
number of persons considering
the mass of the product.
This pump is neither dust-proof nor
explosion-proof. Do not use it at a
dusty place or at a place where
toxic, corrosive or explosive gas is
present. Use in such places
could cause fire or explosion.
If a hose is used for the discharge
line, take a measure to prevent the
hose from shaking. If the hose
shakes, you may be wet or
injured.
Provide a countermeasure against
overflow, like installation of a
stand-by pump. If it is insuffi-
cient, the overflow may damage
nearby wall, floor and other
equipment.