Страница 2: ...power supply 8 5 Function and Setting 8 5 1 Test printing 8 5 2 Operation function setting 9 5 2 1 Interface Printing direction setting 9 5 3 Error 10 5 3 1 Paper end detection 10 5 3 2 Temperature er...
Страница 3: ...Please confirm each product incorporates the following accessories 442A Parallel conform to Centronics Serial RS 232C 1 Users Manual 2 Chart paper one roll 3 Main body 4 Power cable Power connector wi...
Страница 4: ...installing this product to cabinet housing make sure to exchange air inside to keep inside temperature under 50 Keep space when installing more than 2 products No space installation between products m...
Страница 5: ...n etc for forced draft in case of installing more than 2 products 2 2 Roll chart WARNNING Do not touch thermal head and its around after printing where high temperature is supposed Replace roll chart...
Страница 6: ...hart in appropriate direction shown in the drawing below Draw a tip of chart paper outward and close a roll chart cover Method of installing roll chart CAUTION Do not bend roll chart inside Paper migh...
Страница 7: ...Dimensions unit mm 1 2 3 4 5 6 7 8 O F F 1 1 A 12V 24V FUNCTION DATA MAX8 3 91 91 53 96 96 20 5 1 2 3 4 5 6 7 8 O F F 1 1A 12V 24V FUNCTION DATA 1 2 3 4 5 6 7 8 O F F 1 1A 12V 24V FUNCTION DATA 20 5...
Страница 8: ...d and temperature error FEED Key One line feeding per one press Continuous feeding by continuous pressing This Key is to setup a chart roll as well Open Close button for chart roll cover Press this bu...
Страница 9: ...t non use 442A E2 USB Connector USB 4P Type A No Signal Function 1 VBUS No use 2 D Input Output USB data 3 D Input Output USB data 4 GND Ground Pin No Cable Color Signal Function Parallel Centronics S...
Страница 10: ...o side and to side CAUSION No isolated between DC power and Input Supply power specified Wrong power might damage the product Get rated power within 1 sec after supply power Wait 10 sec or more before...
Страница 11: ...USB OFF OFF 4800 bps at delivery ON OFF 9600 bps OFF ON 19200 bps ON ON 38400 bps 1 Input interface Invalid at E2 OFF Conform to centronics at delivery ON RS 232C Parallel Conform to centronics setti...
Страница 12: ...blinking 5 4 Interface 5 4 1 Parallel Conform to centronics Timing chart Receive Buffer Full 8 bits data A B C STROBE D E D F BUSY ACK G G Connection 442A 20p 25p D sub connector 1 STB 2 DATA 1 3 DAT...
Страница 13: ...e data stored in the input buffer of printer is 2020 bytes or less the printer sends Xon command to a host When the host receives Xon command the host resend the remained data RS 232C Connection 442A...
Страница 14: ...a start line to print The control command is not deleted cancellation 6 DEL Deleting a 7FH Deleting a character Deleting a character of the receiving buffer just before entered in the same line The c...
Страница 15: ...the table above due to printing condition CAN CR DEL ESC LF SO SI FS DC2 represent Control Codes SP represents Space 6 Specification 6 1 Model 442A 1 Input Interface 6 2 Performance Power supply 12V...
Страница 16: ...lines sec Max Note Printing rate 16 or less Paper feeding 3 75mm pitch Receiving buffer 2048 bytes Printing width 46mm Life time At 25 Head 109 pulse or more pulse resistance 50km or longer except dam...