4.3 Determine the installation method and location 

ACU series product dimension:   

   

                         

ACU3.0K is cooled by natural wind convection. It is recommended to install in indoors or 

sheltered areas to avoid direct sunlight, rain and snow. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание TSOL-ACU3.0K

Страница 1: ...31 TSOL ACU3 0K...

Страница 2: ...erface Description 17 5 2 System Wiring Schematic 18 5 3 ACU Wiring 18 5 4 Expansion Battery Wiring 21 5 5 DRM Communication Interface Description 24 5 6 CT Meter Installation 25 5 6 1 CT Solution 25...

Страница 3: ...d by qualified personnel 1 3 Symbols Used The following types of safety instructions and general information appear in this document as described below Danger Danger indicates a hazardous situation wh...

Страница 4: ...he inverter or battery pack please disconnect the inverter from all voltage sources as described in this document Warning Installation repair recycling and disposal of ACU must be performed by qualifi...

Страница 5: ...device will release a lot of heat during operation Do not touch metal plate housing of the inverter during operating Caution Do not modify or tamper with ACU and other components of the system Risk o...

Страница 6: ...mended 1 Eye contact Rinse eyes with a large amount of running water and seek medical advice 2 Contact with skin Wash the contacted area with soap thoroughly and seek medical advice 3 Inhalation If yo...

Страница 7: ...system from catching fire 4 Do not expose the damaged battery to the sun to prevent internal heating of the battery Electrical hazard The reason of fire and explosion accidents in lithium batteries is...

Страница 8: ...ing ACU can has a capacity expansion by using TSOL B Expansion Battery In daytime solar power supports the loads first while the surplus power will be stored by ACU to improve self consumption rate In...

Страница 9: ...on Battery System Capacity 1 0 5 1kWh 1 1 10 2kWh 1 2 15 3kWh 1 3 20 4kWh 3 2 Product Model Description TSOL ACU 3 0K TSUN of the brand ACU represents the product series 3 0K indicates the rated power...

Страница 10: ...d Backup Voltage Range V 220 230 240 180 280 Rated Grid Backup Frequency Range Hz 50 60 5 Power factor cos 0 8 leading 0 8lagging Feed in L N PE AC Output Back up Mode Max Continuable Output Power VA...

Страница 11: ...er generation equipment must be performed by qualified personnel in compliance with national and local standards and regulations Note The pollution level applicable to ACU is Class II Inappropriate or...

Страница 12: ...ine the installation method and location ACU series product dimension ACU3 0K is cooled by natural wind convection It is recommended to install in indoors or sheltered areas to avoid direct sunlight r...

Страница 13: ...e installation point is circulated Bad air ventilation will affect the working performance of internal electronic components and shorten the service life of ACU 30CM 30CM 50CM 50CM 50CM The following...

Страница 14: ...please make sure that the wall has sufficient strength to fix the screws and bear the weight of ACU Step 1 Pre check the installation distance of the ACU to other items Step 2 Positioning the Mounting...

Страница 15: ...13 Fix the mounting bracket with hex head screw on the installation positions Step 3 Hang the ACU to the mounting bracket and make sure the device is snugly fits with the bracket...

Страница 16: ...s on those positions 8mm in diameter 50mm in depth by using the mounting bracket as a template and then use a rubber hammer to drive the screw fixing seat into the holes to fix the bracket Note If any...

Страница 17: ...be found below Primary Secondary 1 Secondary 2 Secondary 3 Step 3 After the mounting bracket fixed and before hanging the ACU Expansion Battery on the mounting bracket please remove the plug from the...

Страница 18: ...install Expansion Battery No 3 first Expansion Battery No 2 secondly Expansion Battery No 1 thirdly and ACU finally from bottom to top Please hang the ACU Expansion Battery to the mounting bracket wit...

Страница 19: ...tions 5 1 Electrical Interface Description Object Description A DRMS Port B CT Meter connection C RS232 communication D Grid connection E Backup connection F Ground G BMS switches H Battery switches I...

Страница 20: ...Please unscrew the screws and remove the cover plates on right UPPER side of the ACU for wiring Please be cautious when unplug battery switch cable during dismantling Warning Turn off the Battery Swit...

Страница 21: ...of GRIDL GRIDN and GND2 properly Step 3 Lead another cable Recommend conductor core size 2 5 mm2 through the waterproof nut BACKUP and then use E6012 wire crimps to connect the wires to the terminal o...

Страница 22: ...DRMS GRID_CT PV_CT Step 4 Remove the external hex head screw and lead a grounding line through OT terminal screw it into the grounding port of ACU enclosure in clockwise direction and make sure it is...

Страница 23: ...cted to the BMS Switch inside the cover plate can be plugged out first if needed Warning If no Expansion Battery device wired to the ACU please ignore this section For expanding the system capacity th...

Страница 24: ...from the fastening head of ACU to the fastening head of Expansion Battery 30kgf cm torque is recommended Then press the RJ 45 plugs to the end of the RJ45 cable and connect the cable to the RJ45 termi...

Страница 25: ...ery There is a RJ45 plug being plugged on the COMM 3 port of expansion battery originally please take it out when you are connecting more than one expansion battery but DO NOT take the RJ45 plug out o...

Страница 26: ...plates back to the ACU and Expansion Battery respectively 14kgf cm torque is recommended Step 5 Use a wrench to fasten cable gland of the ACU and Expansion Battery 30kgf cm torque is recommended And i...

Страница 27: ...erter is generating less than 75 of the rated power AND sink reactive power if capable DRM8 4 5 The inverter is generating 100 of rated power Subject to constrains from other active DRMs 5 6 CT Meter...

Страница 28: ...CT buckles 5 Open the PV_CT by pushing the buckle on its side 6 Lead the Live of PV through the PV_CT 7 Tighten up the PV_CT buckles 8 Lead RJ45 plug of the CT line to pass through waterproof CT METE...

Страница 29: ...gle phase or three phase meters based on the Grid and PV system types Cannot use single phase and three phase meters at a same time 5 6 2 1 Two Three Phase Meters In a three phase grid three phase PV...

Страница 30: ...Grid side is 1 5 6 2 2 One Three Phase Meter In a single phase grid single phase PV system one unit of three phase meter shall be used to sample voltage and current Phase C of the meter is used to sam...

Страница 31: ...gle phase meters can be used to sample voltage and current at PV side and grid side Please install the 1 phase meters with reference diagram as showed below Please set the meter address Grid side into...

Страница 32: ...will jump to the initial display interface and no further operation is required to start the meter 5 6 3 2 Three Phase Meter The setting methods for three phase meter is as follows Power on the meter...

Страница 33: ...reaker and Residual Current Device Please install a circuit breaker to ensure the inverter is able to disconnect from grid safely The inverter is integrated with a RCMU however an external RCD is need...

Страница 34: ...re being upgrade Red lamp Always light on Faults in device B Residual battery capacity percentage SOC Total remained battery capacity of the system 6 2 Start up the System If only ACU is installed the...

Страница 35: ...ndicators on the front of ACU to check the running status of the 4 If the system is running normal please do commission configuration If the system is not work normally please re check the wiring and...

Страница 36: ...34 3 Do the local setting by Applications Local Mode Scan the QR code in the monitor logger 4 Connect WLAN to the Wireless Access Point of monitor logger...

Страница 37: ...35 5 Set the battery type by Basic Setting Bat Parameters Bat Type Select Lithium battery 6 Set the Safety Standard by Basic Setting Safety Type 7 Set the CT Meter type by Basic Setting Meter_enable...

Страница 38: ...ystem will firstly be used to support the home loads The surplus electricity will be used to charge the battery by ACU Once the battery of ACU is full the more surplus electricity will be fed into the...

Страница 39: ...t Revenue from TOU price management is mainly obtained through price difference and adjustment of electricity utilization plan Up to seven charge and discharge controls can be set in this mode Time da...

Страница 40: ...nual Maintenance Mode is only used to do the maintenance work by qualified personnel 10 Set the ACC_EPSEn to Enable in the work mode page 11 Battery info Inverter info and Power production statistics...

Страница 41: ...orization Solarman Business APP 1 Log in Solarman Business APP and find the creating page in Business Monitor 2 Fill in the information of the plant and click Save Pay attention that the System Type s...

Страница 42: ...way Logger and scan the QR code of the monitor logger 4 Click Authorize Users and authorize this plant to the End User If the end user doesn t have an account click create a New User and create a new...

Страница 43: ...Business Web 1 Visit pro solarmanpv com and log in Solarman Business Website 2 Find the creating page in Monitor Plants Create a Plant 3 Fill in the information of the plant and click Save Pay attenti...

Страница 44: ...42 4 Click Add a New Gateway Logger and input the SN of the monitor logger...

Страница 45: ...the correct sequence as follows 1 Turn OFF the Battery switch on the right side of the ACU Expansion Battery 2 Press approx 5 seconds the BMS switch on the right side of the ACU Expansion Battery unti...

Страница 46: ...voltage low Master Error 17 Bus voltage high of hardware Master Error 18 Inverter overcurrent Master Error 19 Inverter hardware overcurrent Master Error 20 Inverter short circuit fault Master Error 21...

Страница 47: ...nate machine Slave Error 66 Storage fault Slave Error 67 RTC fault Slave Error 68 BMS equipment fault Slave Error 81 Unit cell over voltage alarm Slave Alarm 82 Unit cell under voltage alarm Slave Ala...

Страница 48: ...should be stored in accordance with the storage requirements mentioned above and the battery should be installed within 6 months since delivered from the factory and used with compatible inverters The...

Страница 49: ...47...

Отзывы: