ZIP MASTER
ZIP MASTER
ZIP MASTER
ZMEL0200U
□□
G
(Frequency or input motor rpm)
Pulses per motor revolution (mm)
Motor size (kW)
*1 Special strokes are also available. Contact a Tsubaki representative for more information.
*2 Servomotor driver, motor cable, brake cable, and encoder cable are not included. They need to be prepared by the customer.
*3 400V AC class is also available. Contact a Tsubaki representative for more information.
1.96
{
200
}
588
{
60
}
60
{
1,000
}
(
70Hz
)
28.58
3.7
1/10
ZMEL0500H
□□
G
With three-phase motor
4.90
{
500
}
1,960
{
200
}
48
{
800
}
(
84Hz
)
19.05
Three-phase/four-pole high-efficiency motor
with non-excitation type brake
5.5
1/15
ZMEL1000M
□□
G
9.80
{
1,000
}
4,900
{
500
}
19.8
{
330
}
(
69Hz
)
9.53
5.5
1/40
ZMEL0200U
□□
K
1.96
{
200
}
588
{
60
}
60
{
1,000
}
(
2,100r/min
)
28.58
HG-SR352BK
3.5
1/10
ZMEL0500H
□□
K
With servomotor
4.90
{
500
}
1,960
{
200
}
48
{
800
}
(
2,520r/min
)
19.05
Mitsubishi Electric Corp. servomotor (with brake)*
2
HG-SR502BK
5.0
1/15
ZMEL1000M
□□
K
9.80
{
1,000
}
4,900
{
500
}
19.8
{
330
}
(
2,598r/min
)
9.53
HG-SR502BK
5.0
1/50
1,500, 2,000*
1
200V AC class
Chain, guides: Grease (No. 2)
Acrylic lacquer-based, cream (B27-90B)
ZME
L
0500
H 15
G
L1
ZME
L
1000
M 20
K
V
Option
G
K
Option
1 additional position
detection sensor
Motor voltage 400V
class
With rotary encoder
Lift load/speed code
0200U
0500H
1000M
Lift load
1.96kN
4.90kN
9.80kN
Speed
1,000mm/s
800mm/s
330mm/s
Code
15
20
Stroke
1,500mm
2,000mm
Model Numbering
Allowable Overhung Load
Center of gravity position
[
mm
]
Lift load
[
kN
]
0
0
1.96
4.90
9.80
100 200 300 400 500 600 700 800 900 1,000
ZME1000
ZME0500
ZME0200
Ambient Conditions
Relative humidity
Altitude
Atmosphere
Mounting direction
Indoor not exposed to dust or water
0 to 40°C
85% RH (no condensation)
1,000 m or less
Less than 1G
Horizontal
With three-phase motor
With servomotor
Manufacturer
Model number
Product name
Surge Absorber
Ceramic Varistor
Panasonic
Nippon Chemi-Con
ERZV14D471
TND14V-471KB00AAA0
Model
Rated load (kN)
{
kgf
}
Allowable OHL (N
・
m) {kg f
・
m}
Nominal speed (mm/sec)
Stroke (mm)
Motor
Power supply voltage*
3
Reduction ratio
Lubrication
Coating
Specifications
ZMEL0200U
ZMEL0500H
ZMEL1000M
: Extending
: Extending
: Retracting
ZMEL0200U
ZMEL0500H
ZMEL1000M
: Retracting
: Retracting
: Extending
U
R
V
S
W
T
U
T
V
S
W
R
Three-phase Motor Wiring and Lifting Direction
The brake voltage is 90 VDC.
(When inputting 200 VAC to DM200D or PM180B)
When using a 3.7 kW motor, the brake power supply module
can be damaged depending on the wiring length, wiring
method, relay type, or other factors. Connect a varistor
between the separate DC switching terminals.
For *1 in the diagram, use an auxiliary relay (MCa) with a
contact capacity of 200 VAC / 7 A or more (resistive load).
When using an MC auxiliary contact or auxiliary relay for *2 in
the diagram, use a device with a contact capacity of 200 VAC /
10 A or more (resistive load).
Connecting closer to the brake power supply module (blue
lead wire) will be most effective. The specific model numbers
of the varistors are as follows. Select a varistor voltage of
470 V for DM200D.
*1
*2
*3
*4
Ⓜ
: Motor,
Ⓑ
: Brake, MC: Magnetic contactor, MCa: Auxiliary relay, OCR: Overcurrent relay, DM200D/PM180B: DC module,
-N-: Protection element (varistor)
3.7 kW
5.5 kW
*1
200–220 VAC
PM180B
*1
*2
200–220 VAC
DM200D
Set the base frequency at 60 Hz.
Set the base frequency at 60 Hz.
Three-phase Motor Wiring
(for inverter only)
Inverter
Yellow
Yellow
Black
Black
Blue
Blue
Power sour
ce
Inverter
Yellow
Yellow
Black
Black
Power sour
ce
Adjustment Procedure
1. Move ZIP MASTER to the specified
position. (Ascending or descending)
2. Temporarily loosen the sensor
mounting screws (cross-shaped
recessed rounded head screws; M4
× 8), and move the sensor up or
down to adjust the detect position.
Note: See the inspection procedure on
page 32 to remove the cover.
Limit sensor mounting position
▶
Position Detection Sensor Specifications
A total of four limit sensors are installed, two for upper and
lower limit stroke sensors, and two for upper and lower
limit speed reduction sensors.
* OUT1: ON when light is on; OUT2: ON when light is off
Manufacturer
Model
Supply voltage
Operation mode
Output specifications
OMRON Corporation
EE-SX972-C1
5 to 24 VDC ±10% (Load current: 50 mA or less)
NC, NO switchable
NPN open collector type
Electric circuit
Load 2
Main
circuit
Load 1
24 VDC
White (OUT2)*
Brown (+)
Black (OUT1)*
Blue (-)
Upper limit
sensor
Lower speed
reduction
sensor
Lower limit
sensor
Upper speed
reduction
sensor
Sensor
mounting
screws
Limit
sensor
Sensor
dog
Move up or
down along
the sensor rail
Position Detection Sensor
Series
Linear guide
Rated load
Speed
Stroke
Stroke
Drive
Drive style
Rated load
Speed
Gear motor
Servomotor, etc.
(Workpiece mounting surface:
Refer to outline dimensions)
Free from corrosive gases,
explosive gases, and steam
Installation place
Ambient
temperature
Shock resistance
value
L1
V
E
25
26