9/14
6 Connecting Links
Tsubaki plastic Cableveyors may be packaged and shipped disassembled in set unit lengths. Use the following
method to connect the Cableveyor to the desired length.
*91H80 (inner height 80mm) Left and right links are the same.
1) To connect two disassembled Cableveyors, remove the arms and lock stays (if present) on the links of each
end to be connected.
2) Align the links to be connected and press together laterally. Links will fit together with a loose snap fit.
Then, push together firmly by hand or tap lightly with a plastic hammer until the link ends touch and they are
firmly connected. Once joined, attach the arms.
㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷 㩷
*Open type arm