background image

14/14

Note: 1.    The difference between bracket centers on both ends should be less than 6mm. 

  2.    The bracket installation height is (H + 10

30mm). Do not install so that it places undue force on the 

Cableveyor. 

  3.     Cableveyor sag and bow will change slightly depending on temperature fluctuations and cable/hose 

weight. This does not pose a problem in use. 

*Important points in inserting cables and hoses 

1)    Insert cables and hoses so that lift slightly over the lock stay (arm) where articulating as shown below. 

Fix both ends of the cables/hoses and ensure their length in the Cableveyor does not fluctuate after use 
(operation). 

2)    Remove any twists or kinks from the cables/hoses and ensure they lay straight in the Cableveyor. 

Note: Remove all twists/kinks from the cables/hoses, fix both ends, and ensure length in Cableveyor does not 
fluctuate.

*After-installation inspection 

1)    Ensure there is no foreign matter on the guide rail, as it may cause the Cableveyor to meander or damage it. 
2)    Let it run a full stroke and ensure that the specified Cableveyor leeway length is present. 
3)    Ensure there is no undue tension on the cables/hoses during movement. (Refer to points above.) 

10 

Maintenance and Inspection

1)    The Cableveyor does not need to be lubricated. 
2)    Sitting atop or placing heavy objects atop the Cableveyor may damage it. 
3)    Take precautions to ensure that foreign matter does not fall into or collect on the guide rail.   
4)    Ensure the Cableveyor’s return stroke is smooth, and that there is no undue tension on the cables/hoses.
5)    Ensure there are no cracks in the Cableveyor or abnormal wear on its surface. 

 

Parallelism 

Note: 1 
  Center difference

Note: 3 

Bow

Sag

Cable

Floor

Fixed End Bracket 

Equipment

Note: 2   

Installation height 
(H + 10 – 30mm)

Moving End 
Bracket 

Cable 

Cableveyor 

Cables/Hoses

Arm

Ensure it is loose enough to lift a bit over the lock stay 
Lock Stay    Note: 1

Cableveyor meanders easily from rebound    Direct 

Note: 1 

Good

Note: 1

Fixed

Fixed 

Содержание TKC91

Страница 1: ...91 Plastic Cableveyor Instruction Manual Closed typeArm Hinge Link Bracket A Bracket B Bush Lock Stay Open typeArm Vertical Divider usable either side Vertical Divider Horizontal Divider DSAtype Horiz...

Страница 2: ...mage parts 4 Wear gloves safety glasses safety shoes and other protective gear as appropriate when working 3 Arm Types and Removal All TKP91 open type arms are interchangeable Caution 1 Hold down the...

Страница 3: ...ingers into the space under the lifted arm and lift and hold up Next insert the screwdriver slightly between the groove on the top of the link and the underside of the arm and pull the screwdriver dow...

Страница 4: ...diagram and twist to lift arm This may release the hook side at the same time Flat End 2 If the hook side does not release insert a screwdriver about 7mm into the release hole on the flat side of the...

Страница 5: ...nhook the side and twist the entire arm while lifting up to remove 4 Arm Types and Assembly TKP91 open type arms are interchangeable 1 Ensure the link cannot move Align an arm parallel with the instal...

Страница 6: ...with the link end Attachment area not parallel TKC91 closed type arm 1 Closed type arms consist of the arm itself and two hinges If there are only hinges in the link then hold the arm vertically on t...

Страница 7: ...parallel to the installation area of a secured link Then tap lightly from directly above as indicated by the arrows below to attach Lock stays will not insert if they are misaligned Forcing lock stay...

Страница 8: ...ableveyor interior unless installed as shown below Overlap Moving end bracket side from above Attach to equipment Note Install as shown in the diagram 2 There is an assembly direction for arms and loc...

Страница 9: ...t links are the same 1 To connect two disassembled Cableveyors remove the arms and lock stays if present on the links of each end to be connected 2 Align the links to be connected and press together l...

Страница 10: ...lock stays on the two links at each end to be connected 2 Align the links to be connected and press together along the direction of pitch Links will fit together with a loose snap fit Then push toget...

Страница 11: ...Once the links have been separated slightly insert the screwdriver further and separate totally Do not force apart one side only ensure that the opening is uniform when separating Note The Cableveyor...

Страница 12: ...e types of dividers The slide and lock types have the same shape but one has a protrusion while the other does not The top and bottom of the divider on each side is different Slide Type Lock Type Dual...

Страница 13: ...on the equipment Moving end bracket TKP91 H80 Can be mounted on either side TKC91 H80 Mount so that foreign matter cannot get inside cover space see pg 8 TKP TKC91 H56 Mount on bracketA B side Fixed...

Страница 14: ...on 1 Ensure there is no foreign matter on the guide rail as it may cause the Cableveyor to meander or damage it 2 Let it run a full stroke and ensure that the specified Cableveyor leeway length is pre...

Отзывы: