UMD PSU-22
10
V4.0
6.0
The Internal Power Supplies
These are Mean Well SP-300 Series units. In the event of a failure the faulty item should be returned
to TSL for replacement.
The user should not attempt any repairs as this voids the PSU manufacturer’s warranty.
Manufacturer’s Specification
Model SP- 300-24
DC Output Voltage
24V
Output Voltage Tolerance
1%
Output Rated Current
12.5A
Output Current Range
0 – 12.5A
Ripple and Noise
150mV pk-pk
Line Regulation
0.2%
Load Regulation
0.5%
DC Output Power
300W
Efficiency
86%
DC Voltage Adjustment
20 ~ 26.4V
Input Voltage Range
88 264VAC 47 63Hz; 124~370VDC
AC Current
4A/115V, 2A/230V
Power Factor
0.9/100 240VAC
Inrush Current
18A/115V 36A/230V
Leakage Current
1mA/240VAC
Overload Protection
105 135% Type: Pulsing Hiccup Shutdown Reset:
Auto Recovery
Over Voltage Protection
27.6-32.4V
Fan Control Over Temp Protect.
RTH1 or RTH2 50 C Fan On,
45 C Fan Off
70 C Output Shutdown
Temp. Coefficient
0.03%/ C (0 50 C)
Setup, Rise, Hold up Time
1.5s, 50ms, 20ms
Vibration
10 500Hz, 2G 10min./1cycle, Period for 60min each
axis
Withstand Voltage
I/P-O/P:3KVAC I/P-FG: 1.5KVAC
O/P-FG:0.5KVAC
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100Mohms
Working Temp. Humidity
-10 C-+50 C (Refer to O/P de-rating Curve), 20%-90%
RH
Storage Temp. Humidity
-20 C +85 C, 10% 95% RH
Dimensions
215*115*50mm Case 912
Module weight
1.2Kgs
Safety Standards
UL1950, TUV EN90950 Approved
EMC Standards
CISPR22
(EN55022),
IEC1000-4-2,3,4,5,6,8,11
IEC1000-3-2 Verification
Notes:
1. All parameters are specified at 230V I/P, rated load, 25 C, 70% RH ambient
2. Ripple and noise are measured at 20MHz using a 12” twisted pair terminated with a 0.1uF and 47uF
capacitor.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured for 0% to 100% rated load.