Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
Power Loop Setting
7.2
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
29
0x202C
Power Loop
Setting
—
0x00000000~0x0003000F 0x00020001
Restart
Byte0: Input main voltage of power module
0x00-Three-phase 200V;
0x01-Three-phase 220V;
0x02-Three-phase 240V;
0x07-Single phase 200V;
0x08-Single phase 220V;
0x09-Single phase 240V.
Byte1: Reserved. The default value is 0.
Byte2: Motor drive module model selection
0x00-CDRC-002;
0x01-CDRC-003;
0x02-CDRC-005;
0x02-CDRC-008.
Byte3 reserved, the default is 0.
Parameter Description:
Byte0 is used to set the input power supply voltage type of RC series servos. At present, the power input of the
product only supports single phase and three-phase voltage below 240V.
Byte2 is used to set the model of a motor drive module. If the set drive model does not match the actual drive
model, the drive initialization will fail, reporting fault "Initializing PWM application" and "Incorrect matching of
main circuit type".
User permission:
User/Engineer.
Parameter permission:
Read and Write
107
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...