MCERTS PM2.5 Indicative Certification 

 

854001-M1 DustTrak

™ Environmental Monitor 

 

854021 PM2.5 Impactor (must be installed) 

 

854041 Heated Inlet with Omni-directional Inlet and water trap (must be installed) 

 

PCF set at 0.33 (preset at the factory). It is recommended that the instrument is run with a 
Photometric Correction Factor (PCF) of 0.33. However, the application of a site specific correction 
factor may be used if a significant decrease in the expanded uncertainty can be demonstrated. 

MCERTS PM10 and PM2.5 Indicative Certification 

 

854301-M1 DustTrak

™ Environmental Monitor 

 

854041 Heated Inlet with Omni-directional Inlet and water trap 

 

PCF PM2.5 set at 0.47, PM10 set at 0.53 (preset at the factory). It is recommended that the 
instrument is run with these Photometric Correction Factors. However, the application of site specific 
correction factors may be used if a significant decrease in the expanded uncertainty can be 
demonstrated. 

Installation and Set Up 

Overview 

This manual follows an order of assembly steps listed below, with reference to applicable accessories 
needed for MCERTS certification. For further information, refer to the manuals for the photometer itself 
and the DustTrak

™ Environmental Monitor. 

1.  Refer to Chapter 3 of the DustTrak

™ Environmental Monitor operation and maintenance manual 

(P/N 6012056) for the initial setup of the instrument. Complete steps 1 through 5. 

2.  Assemble the heated inlet column from parts contained within the Heated Inlet (854041), and PM10 

and PM2.5 Impactor Kits (854020/854021). 

NOTE

 

The Impactor Kits are only needed for PM2.5 and PM10 models. They should not be used/installed 
on to the DRX version instruments. 

Содержание DUSTTRAK 854001-M1

Страница 1: ...DUSTTRAK ENVIRONMENTAL MONITOR MCERTS VERSIONS ASSEMBLY GUIDE P N 6010298 REVISION C FEBRUARY 2021...

Страница 2: ...mes and mist This instrument use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance The below models are designed...

Страница 3: ...instrument is run with these Photometric Correction Factors However the application of site specific correction factors may be used if a significant decrease in the expanded uncertainty can be demons...

Страница 4: ...Omni Directional Inlet as shown NOTE For best results use PTFE Thread Sealant Tape on the water bottle threads 2 Unscrew the PM2 5 or PM10 impactor to access the impactor plate as it comes pre assembl...

Страница 5: ...Sample Conditioner column by pushing it down 6 Ensure the O ring included with the Impactor Kit is installed into the bottom of the Impactor housing 7 Thread hand tighten the impactor housing with O...

Страница 6: ...Heated Inlet 854041 into Environmental Enclosure 1 Attach heated inlet control module to the front of the Photometer This can be done using the 2x 6 32 x 5 16 Socket Head Cap Screws and 2x flat washe...

Страница 7: ...wn Sun Shield should not touch sintered cap of RH Temp Probe 5 Attach RH Temp Sensor cable to heated inlet control module J3 6 Attach the two larger gray connectors to side of the photometer 7 Attach...

Страница 8: ...nting ring rotate slowly until alignment pin mates with the hole in the bottom of heated inlet column 10 Slide column retainer ring down heated inlet column 11 Hand tighten column retainer ring to sec...

Страница 9: ...oming air and thereby decrease RH to the targeted level NOTE By default TSI Incorporated TSI sets the RH set point to 30 RH at the factory If needed this can be adjusted to meet other application need...

Страница 10: ...trol module 7 in x 1 5 in x 0 75 in 17 8 cm x 3 8 cm x 1 9 cm Temp Range 0 to 50 C 32 to 122 F RH Range 0 to 95 RH Set Points 30 RH 40 RH 50 RH Warm up Time 17 minutes CE IEC 61326 IEC 61010 1 Instrum...

Страница 11: ...11 This page intentionally left blank...

Страница 12: ...strations DustTrak is a trademark of TSI Incorporated TSI Incorporated Visit our website www tsi com for more information USA Tel 1 800 680 1220 UK Tel 44 149 4 459200 France Tel 33 1 41 19 21 99 Germ...

Отзывы: