TSI Instruments DUSTTRAK 854001-M1 Скачать руководство пользователя страница 1

  

 

 

DUSTTRAK

 

ENVIRONMENTAL

 

MONITOR 

MCERTS

 

VERSIONS 

 

ASSEMBLY GUIDE 

 
 
 
 

P/N 6010298, REVISION C 

FEBRUARY 2021 

 
 

 

 

 

Содержание DUSTTRAK 854001-M1

Страница 1: ...DUSTTRAK ENVIRONMENTAL MONITOR MCERTS VERSIONS ASSEMBLY GUIDE P N 6010298 REVISION C FEBRUARY 2021...

Страница 2: ...mes and mist This instrument use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance The below models are designed...

Страница 3: ...instrument is run with these Photometric Correction Factors However the application of site specific correction factors may be used if a significant decrease in the expanded uncertainty can be demons...

Страница 4: ...Omni Directional Inlet as shown NOTE For best results use PTFE Thread Sealant Tape on the water bottle threads 2 Unscrew the PM2 5 or PM10 impactor to access the impactor plate as it comes pre assembl...

Страница 5: ...Sample Conditioner column by pushing it down 6 Ensure the O ring included with the Impactor Kit is installed into the bottom of the Impactor housing 7 Thread hand tighten the impactor housing with O...

Страница 6: ...Heated Inlet 854041 into Environmental Enclosure 1 Attach heated inlet control module to the front of the Photometer This can be done using the 2x 6 32 x 5 16 Socket Head Cap Screws and 2x flat washe...

Страница 7: ...wn Sun Shield should not touch sintered cap of RH Temp Probe 5 Attach RH Temp Sensor cable to heated inlet control module J3 6 Attach the two larger gray connectors to side of the photometer 7 Attach...

Страница 8: ...nting ring rotate slowly until alignment pin mates with the hole in the bottom of heated inlet column 10 Slide column retainer ring down heated inlet column 11 Hand tighten column retainer ring to sec...

Страница 9: ...oming air and thereby decrease RH to the targeted level NOTE By default TSI Incorporated TSI sets the RH set point to 30 RH at the factory If needed this can be adjusted to meet other application need...

Страница 10: ...trol module 7 in x 1 5 in x 0 75 in 17 8 cm x 3 8 cm x 1 9 cm Temp Range 0 to 50 C 32 to 122 F RH Range 0 to 95 RH Set Points 30 RH 40 RH 50 RH Warm up Time 17 minutes CE IEC 61326 IEC 61010 1 Instrum...

Страница 11: ...11 This page intentionally left blank...

Страница 12: ...strations DustTrak is a trademark of TSI Incorporated TSI Incorporated Visit our website www tsi com for more information USA Tel 1 800 680 1220 UK Tel 44 149 4 459200 France Tel 33 1 41 19 21 99 Germ...

Отзывы: