10
Gap/Black Mark
Sensor Calibratio,
Label Length
Measurement,
Self Test and enter
Dump Mode
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes
amber
and blinking.
(Any amber will do during the 5 blinks).
The LED color will be changed as following order.
Amber
red (5 blinks)
amber (5 blinks)
green
(5 blinks)
green/amber (5 blinks)
red/amber (5
blinks)
solid green
It calibrates the sensor and measures the label length
and prints internal settings then enter the dump mode.
Note:
Please select gap or black mark sensor by GAP or BLINE
command prior to calibrate the sensor.
For more information about GAP and BLINE command,
please refer to TSPL2 programming manual.
Printer
Initialization
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns
green
after 5 amber
blinks.
(Any green will do during the 5 blinks).
The LED color will be changed as following:
Amber
red (5 blinks)
amber (5 blinks)
green
(5 blinks)
green/amber (5 blinks)
red/amber (5
blinks)
solid green
Always do
gap/black mark sensor calibration
after
printer initialization.
Force Black Mark
Sensor Calibration
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns
green/amber
after 5
green blinks.
(Any green/amber will do during the 5 blinks).
The LED color will be changed as following:
Amber
red (5 blinks)
amber (5 blinks)
green (5
blinks)
green/amber (5 blinks)
red/amber (5
blinks)
solid green