4.3 Power-on Utilities
Power-on Utilities
provides the basic functions and can be activated by below procedures:
Turn off
the power >
Hold
the Feed button >
Open
the power >
Release
the button depending on the the color of the LED.
Sequences of the settings:
LED Colors
Functions
Amber
Red
(5 blinks)
Amber
(5 blinks)
Green
(5 blinks)
Green
/
Amber
(5 blinks)
Red
/
Amber
(5 blinks)
Solid green
1. Sensor Calibration
(Gap / black mark sensor)
Release
2. Self-Test
(And enter dump mode)
Release
3. Factory Default
Release
4. Bline Calibration
Release
5. Gap Calibration
Release
6. READY
(Skip AUTO.BAS)
Release