8
Parameter
code
Function
Range and allowed values
Notes
Show device code;
-
Show device code and firmware version
alternately;
Working parameters
modification;
0
Active;
1
Inactive;
Decimal point;
0
Inactive;
1-5
from 1 to 5 decimal digit;
Division ratio;
00.00÷999.999
Default =
1.00
Division ratio = (encoder frequency)/(desired value);
First treshold;
From
000000
to
999999
;
Second treshold
From
000000
to
999999
;
OUT 1 logic;
0
Positive logic;
1
Negative logic;
2
Positive pulse;
3
Negative pulse;
Timer OUT 1;
from
00,00
to
99,99
seconds;
if
=0 or 1, the set value delays
OUT 1 activation;
if
= 2 o 3, the set value is the
pulse duration;
OUT 2 logic;
0
Positive logic;
1
Negative logic;
2
Positive pulse;
3
Negative pulse;
Timer OUT 2;
from
00,00
to
99,99
seconds;
if
=0 or 1, the set value delays
OUT 1 activation;
if
= 2 o 3, the set value is the
pulse duration;
Speed value acquisition
time;
from
0,1
to
9,9
seconds;
Set the maximum time between one
speed visualization and the other;
Bold
and framed values are default ones;
Содержание TS010