GS/
VIPER
50DS
PROBLEM
CAUSE
SOLUTION
The engine does not
automatically accele-
rate
-The diesel engine is not
warm enought, the green light
is not on.
-Poor alignment of the vision
area of the radar
-30 amp fuse melted
-Radar interference
-Radar problem
-Waint until the temperature is
higher and the green light is on
(see page 48)
-Check if the radar is horizontal.
-Check the fuse, see p.49
-Check if there is no branche
above the arch and/or if the lips
are not put upwards above the hol-
der
-Switch off the engine and check
at the back of the radar if the en-
gine is warm and if, 10 seconds
after making contact:
* the 1st green light is on
* the 2nd yellow light is on
when a person is detected behind
the hopper of the chipper
* if the 2nd light is blinking red:
contact the seller
The engine remains
at maximum speed
-The feeding unit is not lowe-
red completely
-The sensor for the end of the
chipping activity is disturbed
-Check of the feeding arms are
resting on their silentblocs
-Check the setting of the sensor
(see sensor
(A)
p.49)
P R O B L E M - S O L V I N G
C O 2 R E D U C T I O N ( o p t i o n )
Operating switch CO2 RÉDUCTION activated
Содержание Saelen GS/VIPER50DS
Страница 1: ......
Страница 2: ......
Страница 56: ...GS VIPER50DS ENGINE OIL CHANGE HOSE do the oil change hot HYDRAULIC COUPLING...
Страница 57: ...GS VIPER50DS 57...
Страница 58: ...GS VIPER50DS...
Страница 59: ...GS VIPER50DS...
Страница 60: ...GS VIPER50DS...
Страница 61: ...GS VIPER50DS...
Страница 62: ...GS VIPER50DS...
Страница 65: ......
Страница 66: ......