MAINTENANCE SECURITY
1) Put the parking brake on, remove the ignition key and wait till all the moving parts
have stopped before performing maintenance or repairs.
2) Make sure you put back all the protection screens after servicing.
LUBRICANT quantities
:
Diesel motor: 9,5 L.
Fuel: 45 L.
Hydraulic oil: 24 L.
Hydraulic meter oil: 2,4 L.
Hydraulic reductor feed roller: 1 L.
M A I N T E N A N C E
Recommended LUBRICANT:
1) Lubricant for the hammers of the rotor:
You
must
use a water-resistant lubricant of type NLGI grade 2
"SAELEN BIOPLEX "
2) Lubricant for bearings, transmission belts and different organs:
Use a versatile high grade SAE lubricant that is compatible with extreme pressures
"SAELEN BIOPLEX "
3) Hydraulic oil:
Use oil AFNOR NFE 48600 Types HV iso VG 46
"MINERVA BIO HYDRO 46 "
4) Oil for hydraulic coupling
Use oil AFNOR NFE 48600 Types HV iso VG 46
"MINERVA BIO HYDRO 46 "
5) Engine oil
Use SAE 15W40 which complies with the standards: API CH4-CG4-CF
"MINERVA POWER LONG WAY 15W-40 "
6) Oil feeding reduction valve:
SAE 90 EP