L1102 © Trynex International 2007
5 — 32
Opti-Flow Installation Instructions
Step 1:
Remove original baffles and plug holes with supplied hardware.
Step 2:
Position new style baffle so there is no gaps, baffle is designed to be self locating.
Step 3:
Mark and drill holes.
Step 4:
Install supplied hardware the same way as original baffle was. Nut and washer should be on exterior surface.
Step 5:
Center the Opti-Flow vibrator horizontally and 6-1/2" below apron (see illustration below) mark and drill holes.
Step 6:
Mount vibrator with cord pointing down using supplied hardware. Please note: there are
SPECIAL DOMED WASHERS
that must be
positioned properly. Please refer to standard vibrator instructions for details regarding harness installation, etc.
6-1/2”
CORD FACING DOWN
OPTI-FLOW VIBRATOR