Truvox International Valet BackPack Скачать руководство пользователя страница 9

 

10.  Technical specification 

 
All models: 230-240v / 50Hz, Class II construction. Fitted with 15m supply cord and 13A

 

fused plug. 

 

Model 

 

Valet BackPack 

Code 

 

VBP 

Voltage 

v / Hz 

230-240/50 

Vac motor 

1400 

Protection class 

IP 

20 

Dust capacity 

Airflow 

l/sec 

52 

Vacuum  

kPa 

25 

Vacuum 

mm/wg 

2540 

Sound  pressure  level 
(see note 1) 

dB(A) 

75 

Cable length 

15 

Size  

cm 

60 x 30 x 25 

Weight empty 

kg 

4.5 

Warranty 

 

1 year 

 

1 – Sound pressure level under normal operating conditions is less than 80 dB(A) when measured at a 
distance of 1 metre from machine and 1.6 metres above the floor. Measurements recorded using hand held 
meter. 

Truvox International is a BSI Registered Company and our policy is one of continuous development.  
We reserve the right to change specifications without prior notification. 

11.  Accessories  

 
Accessory 

Part No. 

Description 

Dust bags  

U2-U11-078 

Pack of 10 paper bags 

Hose 

U2-U11-085 

Hose 

Telescopic wand 

BA10623582 

Wand 

Floor tool 

BA10973582 

Combination  floor  tool  for  use  on 
hard and carpeted floors 

Tool kit 

U2-U11-086 

Inclusive  of  dusting  brush,  nozzle 
and crevice tool 

IMPORTANT: Genuine accessories are only available from authorised Service Agents or the Truvox 
Customer Service Department. 

12.  Fault Diagnosis 

WARNING - Before undertaking maintenance operations or adjustments switch off 
machine and unplug from the electricity supply.
 
The following simple checks may be performed by the operator. 

Problem 

Reason 

Remedy 

Machine not working 

Lack  of  voltage/electrical 
supply. 

Check  fuse  *,  supply  cord,  plug  and 
socket outlet. 

Loss of suction 

Bag full 
Blocked hose or wand 
Motor not working 

Replace bag 
Remove obstruction 
Contact supplier 

Motor is not running 

Broken switch 
Defective power cord 
Defective motor 

Contact supplier 
Contact supplier 
Contact supplier 

 
* If the fuse blows several times, the machine should be checked by an authorised Service Agent. 

Содержание Valet BackPack

Страница 1: ...1 User instructions Valet BackPack Commercial backpack vacuum cleaner 03 8113 0000 Issue 6 10 10 CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE ORIGINAL INSTRUCTIONS...

Страница 2: ...2...

Страница 3: ...ings 5 2 3 Fitting the cloth bag 5 2 4 Fitting the paper vacuum bag 6 2 5 Fitting the hose handle wand and floor tool accessories 6 3 Controls 7 4 Operation 7 5 Storage 7 6 Maintenance 7 7 After Sales...

Страница 4: ...d persons away from the machine when in use Before using the appliance check that the mains power voltage corresponds with the voltage shown on the rating plate All parts are to be positioned as indic...

Страница 5: ...ase refer to the technical table for details on weight of machine When transporting the machine ensure that all components tanks and removable parts are securely fastened and that the supply cord and...

Страница 6: ...Your BackPack vacuum has been fitted with a thermal overload to protect the motor against damage should the airflow be blocked for extended periods This may occur if the vacuum bag is overfull or if t...

Страница 7: ...maintenance apart from the following checks by the operator Supply cord Regularly inspect sheath plug and cord anchorage for damage or loose connection Body of the vacuum Clean with a damp cloth Clot...

Страница 8: ...damage 3 Neither Truvox nor its distributors shall be liable for any incidental or consequential loss 4 This guarantee is governed by the laws of England This guarantee does not cover any of the follo...

Страница 9: ...st bags U2 U11 078 Pack of 10 paper bags Hose U2 U11 085 Hose Telescopic wand BA10623582 Wand Floor tool BA10973582 Combination floor tool for use on hard and carpeted floors Tool kit U2 U11 086 Inclu...

Страница 10: ...12 TU1AB00017 SWITCH HARNESS ASSY 1 13 TU1AB00018 FILTER ASSY 1 14 U2 U11 149 FILTER FRAME ASSY 1 15 TU1AB00020 MOTOR MOUNT ASSY 1 16 TU1AB00021 MOTOR ASSY 1 17 U2 U11 132 MOTOR COMPARTMENT ASSY 1 18...

Страница 11: ...21 C RELIEF VALVE ADDED 30 11 11 N P D 30 11 11...

Страница 12: ...30 11 11 C NEW RELIEF VALVE 30 11 11 N P D...

Страница 13: ...lowing transposed harmonised European Standards and technical specifications Ref No Title 2006 42 EC Machinery Directive and subsequent amendments 2006 95 EC The Low Voltage Directive and subsequent a...

Страница 14: ......

Страница 15: ......

Страница 16: ...Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com Authorised dealer...

Отзывы: