Truvox International OB452/400 Скачать руководство пользователя страница 7

provided in the outer ring of the skirt, enabling free 
movement when in use (Fig.5). 

 
 
4.9 Fitting the vacuum unit 

  Stand machine upright, and clamp the vacuum unit 

support bracket to the handle tube in the specified 
position. (Refer to the instructions supplied with the 
unit). 

  Rest the vacuum unit on the support bracket with 

the control switch to the rear, and engage the 
locking bar on the back of the unit to secure it in 
position. 

  Push the flexible hose on to the vacuum unit and 

skirt. 

  Plug the electrical lead from the vacuum unit into 

the socket situated on the left side of the handle 
moulding. 

  The machine is now ready for use. The switch 

controlling the vacuum unit is located on the back of 
the unit. The OFF position is marked O. 

 
4.10 Using the vacuum unit

 

IMPORTANT - For maximum suction the sliding 
shutter on the top of the unit must be closed. 

 

Dust collected by the unit is contained within the 
filter bag located behind the front cover. 

 

To replace the filter bag, switch off vacuum unit, 
release front cover catch and lift off cover. 

 

Remove and dispose of used bag. Fit new bag 
and replace front cover.

 

 

5. Storage 

Always unplug and wipe down and dry the machine 
after use. The machine should normally be stored 
with the handle in the fully upright position. 
Wrap supply cord around the handlebar and cable 
winder ensuring that the plug is not trailing on the 
floor. Store the machine in a dry indoor area only. 
Never store the machine with a pad fitted as this 
causes distortion, and results in instability during 
operation. 
 

6. Maintenance 
WARNING - Before undertaking maintenance 
operations or adjustments switch off machine 
and unplug from the electricity supply. 

The machine requires minimum maintenance apart 
from the following checks by the operator. 

 

Supply cord

 - Regularly inspect sheath, plug and 

cord anchorage for damage or loose connection. 

 

Solution tank

 - Check water flow, if restricted 

inspect hoses and tubes for blockage or kinks. 
Dismantle control valve to clean if necessary. 
Check switch interlock for correct operation. 

 

Vacuum unit

 - All dust bags must be changed 

regularly and hoses and connectors checked for 
blockage to avoid unsatisfactory results. 

 

Motor overload cut-out

 - All machines are fitted 

with an automatic reset motor overload cut-out. 

The cut-out will operate to protect the motor from 
overheating by switching the machine off when 
there is excessive friction/resistance to the 
cleaning head on the floor. This is usually caused 
by the stickiness of the pad or floor. Turn the 
cleaning pad over or if both sides are dirty 
replace with a clean pad. It is not possible to 
obtain a good finish on the floor using a dirty pad. 
Should the cut-out operate it will reset 
automatically when the motor has cooled 
sufficiently, usually after 15 - 30 mins. 

IMPORTANT

 - Should the machine fail to operate 

contact the supplier from whom you purchased the 
machine. 
 

7 After sales service 

Should you require after sales service please contact 
the supplier from whom you purchased the 
machine,who will arrange service. Repairs and 
servicing of Truvox products should only be 
performed by trained staff. Improper repairs can 
cause considerable dangers to the user. 

 

8 Guarantee 

Your product is guaranteed for two years from the 
date of purchase, or hire purchase, against defects in 
materials or workmanship during manufacture. Within 
the guarantee period we undertake to repair or 
replace free of charge to the purchaser, any part 
found to be defective,  excluding brushes, drive discs 
and vacuum skirts.  
 
No liability is accepted for damage caused by 
accident, misuse or neglect, or the fitting of other than 
genuine Truvox parts.  Truvox International Limited 
cannot accept reponsibility for repairs performed by 
persons other than a Truvox serivce engineer or an 
authorised service agent. 
 
This guarantee is in addition to your statutory rights 
and does not affect your rights under the Supply of 
Goods (Implied Terms) Act 1973, or in general. 
 
Truvox International Limited policy is one of continual 
product development and we reserve the right to alter 
specifications without prior notice.  
 
 
 

Содержание OB452/400

Страница 1: ...User instructions 200 400 Dual speed 3 6162 Iss 1 01 01 www truvox com Products Rotaries...

Страница 2: ...2 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5...

Страница 3: ...ive disc 6 3 2 Adjusting the handle height 6 4 Operation 6 4 1 Starting the machine 6 4 2 Model 452 400 dual speed 7 4 3 Polishing 7 4 4 Scrubbing and shampooing 7 4 5 Fitting the solution tank 7 4 6...

Страница 4: ...or signs of damage If the power supply cord is damaged it has to be replaced Do not use where hazardous dust is present Do not use in an explosive atmosphere Take care when using a machine near the to...

Страница 5: ...d Pull lever to release solution Release lever to stop flow 7 Socket connector Connection point for vacuum unit lead Drive plate Attachment point for brush or drive disc and pad Cable winder Used to h...

Страница 6: ...tions 4 5 Fitting the solution tank NOTE The solution tank is supplied as an accessory item complete with attachments and fitting instructions Move the handle to the upright position and clamp the tan...

Страница 7: ...ismantle control valve to clean if necessary Check switch interlock for correct operation Vacuum unit All dust bags must be changed regularly and hoses and connectors checked for blockage to avoid uns...

Страница 8: ...se level see note 1 dB A 53 53 53 Noise level with vacuum unit dB A 69 69 69 Handle vibration see note 2 m s 2 5 2 5 2 5 1 Noise levels measured at a distance of 1 metre from machine and 1 6 metres ab...

Страница 9: ...Standard drive disc see note 1 5 3436 retains cleaning pads Flexi drive disc 5 3437 retains cleaning pads Solution tank 5 3438 scrubbing shampooing Anti splash water skirt 5 3439 prevents splashing w...

Страница 10: ...heck operating procedure in instructions Check brush pad for good condition Check correct liquid type quantity Check liquid dilution Allow motor to cool Vacuum unit not working neon indicator lit Moto...

Страница 11: ...ufactured using the following transposed harmonized European Standards and technical specifications BS EN 50081 1 BS EN 55014 1 2 BS EN 60335 1 and BS EN 60335 2 67 and is in conformity with the Machi...

Страница 12: ...12 Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com...

Отзывы: