Truvox International OB452/400 Скачать руководство пользователя страница 6

  Once the machine has started the interlock buttons 

should be released. 

  To stop the machine release both switch triggers. 

 
4.2 Orbis 452/400 dual speed 

The speed selector switch on the dual speed model is 
located on the motor housing. Ensure machine is 
switched off before changing the speed setting. 

 
4.3 Polishing

 

  Fit polishing brush or drive disc and pad suitable for 

the speed of the machine and the surface to be 
polished. (see 

Accessories

). 

  Apply polish to the floor in accordance with the 

manufacturers instructions. 

 

Do not

 keep the machine rotating on one spot for 

more than 3 seconds, as this could cause 
overheating and damage the floor surface. 

 

4.4 Scrubbing and Shampooing 

  For scrubbing or shampooing the solution tank must 

be fitted as described (see 

Fitting the solution 

tank

). 

  Fit a brush or drive disc and pad suitable for the 

surface to be cleaned. (see 

Accessories

). 

 

WARNING - This appliance has been designed 
for use with the brushes specified by the 
manufacturer. The fitting of other brushes may 
affect its safety.

 

  Fill the solution tank with water and an appropriate 

measure of detergent. 

 

IMPORTANT

 - Use only cleaning agents suitable 

for automatic machines i.e. low foaming, and follow 
the chemical manufactuers’ directions regarding 
use, handling, disposal and health and safety 
provisions. 

  Before starting the machine release a liberal 

amount of cleaning solution from the tank to the 
floor. The flow of solution from the tank is controlled 
by moving the left hand lever. Releasing the lever 
stops the flow. 

  Proceed to operate the machine in the normal 

manner, releasing more cleaning solution from time 
to time as required. 

 

Do not

 keep the machine rotating on one spot for 

more than 3 seconds, as this could cause 
overheating and damage the floor surface. 

  Dirty water should not be allowed to accumulate on 

the floor, it should be removed to prevent dirt from 
settling. We suggest using a suction dryer for this 
purpose. 

  When scrubbing/shampooing is complete, unplug 

the machine from the power supply, empty the 
solution tank and clean and dry the machine.  

 

IMPORTANT

 - Dispose of unused cleaning solution 

in accordance with the manufacturer’s directions. 

 

 

 

4.5 Fitting the solution tank

 

NOTE -

 The solution tank is supplied as an accessory 

item, complete with attachments and fitting 
instructions. 

  Move the handle to the upright position and clamp 

the tank support bracket to the handle tube in the 
specified position (Fig.4). (Refer to the instructions 
supplied with the tank). 

  Take the solution tank and pass the ring on the tank 

chain over the left hand operating lever and locate 
the ring in the inside slot on the top of the lever. 
Rest the solution tank on the support bracket with 
the handle tube in the groove on the back of the 
tank. 

  To secure the tank in position, engage the locking 

bar on the back of the tank. 

  Adjust the length of the chain by means of the 

screw and nut adjuster to ensure there is no tension 
on the chain when the flow control lever is not being 
used. 

  Take the plastic tube supplied and push rigid end of 

tube into the connector on the underside of the 
solution tank, and the other end onto the tube at the 
rear of the motor housing. The tank connector is of 
the sealed lock-in type once the tube is connected. 
To release, press down on the orange collar of the 
connector with the finger tips and pull out tube. 

 
4.6 Removing the solution tank

 

 

Pull off plastic tube from machine base.

 

 

Raise locking bar on back of tank.

 

 

Lift off tank and detach chain ring from lever.

 

 
4.7 The vacuum unit 
NOTE -

 The vacuum unit and vacuum skirt are 

supplied as accessory items, complete with 
attachments and fitting instructions.The vacuum unit 
combined with the vacuum skirt provides full dust 
control, eliminating the need to pre-dust or post dust 
the floor. The unit is designed to fit readily to all Orbis 
models. 

IMPORTANT - The vacuum unit is NOT suitable 
for any form of wet cleaning. 

 
4.8 Fitting the vacuum skirt 

  Unplug and lay the machine down with the 

handlebar resting on the floor. Remove the brush or 
drive disc. 

  Stretch and fit the rubber buffer around the brush 

guard. 

  The flexible section of the skirt has a special spring 

sewn into the fabric. Fit this spring section into the 
groove in the rubber buffer. 

  The spring is a reasonably tight fit to prevent 

accidental movement in use and therefore must be 
pulled onto the buffer by stretching. 

  With the skirt on the buffer it can be moved in its 

groove to bring the hose connector to the rear, 
ensuring the base moulding lies in the cut-out 

Содержание OB452/400

Страница 1: ...User instructions 200 400 Dual speed 3 6162 Iss 1 01 01 www truvox com Products Rotaries...

Страница 2: ...2 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5...

Страница 3: ...ive disc 6 3 2 Adjusting the handle height 6 4 Operation 6 4 1 Starting the machine 6 4 2 Model 452 400 dual speed 7 4 3 Polishing 7 4 4 Scrubbing and shampooing 7 4 5 Fitting the solution tank 7 4 6...

Страница 4: ...or signs of damage If the power supply cord is damaged it has to be replaced Do not use where hazardous dust is present Do not use in an explosive atmosphere Take care when using a machine near the to...

Страница 5: ...d Pull lever to release solution Release lever to stop flow 7 Socket connector Connection point for vacuum unit lead Drive plate Attachment point for brush or drive disc and pad Cable winder Used to h...

Страница 6: ...tions 4 5 Fitting the solution tank NOTE The solution tank is supplied as an accessory item complete with attachments and fitting instructions Move the handle to the upright position and clamp the tan...

Страница 7: ...ismantle control valve to clean if necessary Check switch interlock for correct operation Vacuum unit All dust bags must be changed regularly and hoses and connectors checked for blockage to avoid uns...

Страница 8: ...se level see note 1 dB A 53 53 53 Noise level with vacuum unit dB A 69 69 69 Handle vibration see note 2 m s 2 5 2 5 2 5 1 Noise levels measured at a distance of 1 metre from machine and 1 6 metres ab...

Страница 9: ...Standard drive disc see note 1 5 3436 retains cleaning pads Flexi drive disc 5 3437 retains cleaning pads Solution tank 5 3438 scrubbing shampooing Anti splash water skirt 5 3439 prevents splashing w...

Страница 10: ...heck operating procedure in instructions Check brush pad for good condition Check correct liquid type quantity Check liquid dilution Allow motor to cool Vacuum unit not working neon indicator lit Moto...

Страница 11: ...ufactured using the following transposed harmonized European Standards and technical specifications BS EN 50081 1 BS EN 55014 1 2 BS EN 60335 1 and BS EN 60335 2 67 and is in conformity with the Machi...

Страница 12: ...12 Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com...

Отзывы: