Truvox International OB38200 Скачать руководство пользователя страница 8

thumbs  and  squeeze  both  switch  triggers  to 
start the machine (Fig.3). 

WARNING - Never start the machine 
without pads fitted. 
 

  Once the machine has started the interlock 

buttons should be released. 

  To stop the machine release both switch 

triggers. 

Orbis 452/400 dual speed 

The speed selector switch on the dual speed 
model is located on the motor housing. Ensure 
machine is switched off before changing the 
speed setting. 
 

7.2  Polishing 

  Fit polishing brush or drive disc and pad 

suitable for the speed of the machine and the 
surface to be polished. (see 

Accessories

). 

  Apply polish to the floor in accordance with the 

manufacturers instructions. 

 

Do not

 keep the machine rotating on one spot 

for more than 3 seconds, as this could cause 
overheating and damage the floor surface. 

 

7.3  Scrubbing and Shampooing 

  For scrubbing or shampooing the solution tank 

must be fitted as described (see 

Fitting the 

solution tank

). 

  Fit a brush or drive disc and pad suitable for 

the surface to be cleaned. (see 

Accessories

). 

 

WARNING - This appliance has been 
designed for use with the brushes specified 
by the manufacturer. The fitting of other 
brushes may affect its safety.

 

  Fill the solution tank with water and an 

appropriate measure of detergent. 

 

IMPORTANT

 - Use only cleaning agents 

suitable for automatic machines i.e. low 
foaming, and follow the chemical manufactuers’ 
directions regarding use, handling, disposal 
and health and safety provisions. 

  Before starting the machine release a liberal 

amount of cleaning solution from the tank to the 
floor. The flow of solution from the tank is 
controlled by moving the left hand lever. 
Releasing the lever stops the flow. 

  Proceed to operate the machine in the normal 

manner, releasing more cleaning solution from 
time to time as required. 

 

Do not

 keep the machine rotating on one spot 

for more than 3 seconds, as this could cause 
overheating and damage the floor surface. 

  Dirty water should not be allowed to 

accumulate on the floor, it should be removed 
to prevent dirt from settling. We suggest using 
a suction dryer for this purpose. 

  When scrubbing/shampooing is complete, 

unplug the machine from the power supply, 

empty the solution tank and clean and dry the 
machine.  

 

IMPORTANT

 - Dispose of unused cleaning 

solution in accordance with the manufacturer’s 
directions. 

7.4  Fitting the solution tank 

NOTE -

 The solution tank is supplied as an 

accessory item, complete with attachments and 
fitting instructions. 

  Move the handle to the upright position and 

clamp the tank support bracket to the handle 
tube in the specified position (Fig.4). (Refer to 
the instructions supplied with the tank). 

  Take the solution tank and pass the ring on the 

tank chain over the left hand operating lever 
and locate the ring in the inside slot on the top 
of the lever. Rest the solution tank on the 
support bracket with the handle tube in the 
groove on the back of the tank. 

  To secure the tank in position, engage the 

locking bar on the back of the tank. 

  Adjust the length of the chain by means of the 

screw and nut adjuster to ensure there is no 
tension on the chain when the flow control lever 
is not being used. 

  Take the plastic tube supplied and push rigid 

end of tube into the connector on the underside 
of the solution tank, and the other end onto the 
tube at the rear of the motor housing. The tank 
connector is of the sealed lock-in type once the 
tube is connected. To release, press down on 
the orange collar of the connector with the 
finger tips and pull out tube. 

7.5  Removing the solution tank 

 

Pull off plastic tube from machine base.

 

 

Raise locking bar on back of tank.

 

 

Lift off tank and detach chain ring from lever.

 

 

7.6  The vacuum unit 

NOTE -

 The vacuum unit and vacuum skirt are 

supplied as accessory items, complete with 
attachments and fitting instructions.The vacuum 
unit combined with the vacuum skirt provides full 
dust control, eliminating the need to pre-dust or 
post dust the floor. The unit is designed to fit 
readily to all Orbis models. 

IMPORTANT - The vacuum unit is NOT 
suitable for any form of wet cleaning. 

7.7  Fitting the vacuum skirt 

  Unplug and lay the machine down with the 

handlebar resting on the floor. Remove the 
brush or drive disc. 

  Stretch and fit the rubber buffer around the 

brush guard. 

  The flexible section of the skirt has a special 

spring sewn into the fabric. Fit this spring 
section into the groove in the rubber buffer. 

Содержание OB38200

Страница 1: ...tructions Orbis OB38200 OB38400 OB45200 OB45400 OB50200 OB50400 OBLP452 400 Rotary floor cleaning machines 03 6120 0000 Iss 2 03 10 CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE ORIGINAL IN...

Страница 2: ...2...

Страница 3: ...6 Adjusting the handle height 7 7 Operation 7 7 1 Starting the machine 7 7 2 Polishing 8 7 3 Scrubbing and Shampooing 8 7 4 Fitting the solution tank 8 7 5 Removing the solution tank 8 7 6 The vacuum...

Страница 4: ...4 Diagrams...

Страница 5: ...oltage corresponds with the voltage shown on the rating plate All parts are to be positioned as indicated in the instructions before using the machine Do not operate the machine if it malfunctions or...

Страница 6: ...machines without assistance We advise that the manual handling regulations are followed Please refer to the technical table for details on weight of machine When transporting the machine ensure that...

Страница 7: ...d Drive plate Attachment point for brush or drive disc and pad Cable winder Used to hold supply cord in place on handle when machine is not in use Can be turned to enable quick release of cord Motor o...

Страница 8: ...is complete unplug the machine from the power supply empty the solution tank and clean and dry the machine IMPORTANT Dispose of unused cleaning solution in accordance with the manufacturer s directio...

Страница 9: ...aking maintenance operations or adjustments switch off machine and unplug from the electricity supply The machine requires minimum maintenance apart from the following checks by a trained operator Sup...

Страница 10: ...r any of the following Periodic maintenance and repair or replacement of parts due to normal wear and tear 5 This guarantee is governed by the laws of England This guarantee does not cover any of the...

Страница 11: ...Pressure g cm 28 22 18 27 28 22 18 27 Speed rpm 190 190 190 190 380 380 380 Lo hi speed Motor ac induction Motor Rating W 1100 1100 1100 1100 1100 1100 1100 1100 Cable Length m 15 15 15 15 15 15 15 15...

Страница 12: ...ly IMPORTANT Genuine accessories are only available from authorised Service Agents or Truvox Customer Services Department 15 Fault diagnosis WARNING Before undertaking maintenance operations or adjust...

Страница 13: ...13...

Страница 14: ...manufactured using the following transposed harmonised European Standards and technical specifications Ref No Title 2006 42 EC Machinery Directive and subsequent amendments 2006 95 EC The Low Voltage...

Страница 15: ...15...

Страница 16: ...16 Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com Authorised dealer...

Отзывы: