30 ft
16.6 gal / min
Power Cord Grips used in this product: Type “Y”.
Tool Build Quality: Basic insulation
Thermal insulation on motor winding: Class F
1” x 1”
Inlet and Outlet Diameter
Maximum Height / Maximum Value of
Total Manometric Height
50 minutes’ work per 20 minutes’ rest. Daily maximum: 6 hours.
18 AWG
16 AWG
Conductors
Work Cycle
Class I
IPX4
Insulation
IP Grade
115 ft
Maximum Suction Depth
Tank Capacity
26.5 gal
40 gal
Maximum Flow
3
12255
12257
9.5 A
11 A
60 Hz
Hydropneumatic pressure boosting system
Code
Description
Voltage
Frequency
3400 RPM
Speed
Current
Technical Data
Power Requirements
127 V
HIDR-1x100
HIDR-1-1/2x150
Connection to a power source shall be carried out by a
professional electrician following the electric diagram to the right.
Use a separate electric circuit for the pump. This circuit shall
not have conductor with a caliber lower than #12, and shall be protected with a
20 A time delay fuse. Before connecting to motor to the power line, double
check the switch is in the OFF position and that power is equal to what is
indicated in the motor nameplate. If it is operated with lower voltage, the motor
will be damaged..
All the cabling, power connections and ground connection to the system shall be in compliance with
OFFICIAL MEXICAN STANDARDS NOM-001-SEDE, ELECTRIC INSTALLATIONS (UTILIZATION)
or with the local codes
and ordinances. Call a certified electrician.
• The electricity professional connecting the equipment shall comply with the relevant mandatory rules.
• The fixed installation shall have a device to assure the Omni polar disconnection of the power feed.
• Make sure all the electric requirements described in these instructions and in the hydro pneumatic equipment
nameplate shall match the values of power supply capacity.
• The hydro pneumatic equipment is built with a single-phase motor with overload protection using a thermal device
(overcurrent cut) placed in the wiring.
WARNING
CAUTION
CAUTION
Pump
127 V
60 Hz
Pressurestat
Using electric extensions for hydro-pneumatic equipment is not recommended. It causes voltage drop, loss
of power in the motor and overheating.
• In the event of connecting the hydro pneumatic equipment into a fuse protected circuit, use delay action fuses Type “D”.
CAUTION
ENGLISH
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.