Risk Control When Using

Pneumatic Tools

   

         • Compressed air out of pneumatic 

equipment may be dangerous. Objects like brackets, burrs, 

splinters, dust and other residues may be impelled towards 

head and eyes due to high speed of the air flow.  The air 

flow itself can only injure soft tissue such as eyes, ears, etc.

   

       • The tool attachments may get lose or 

break and project particles towards the operator or other 

operators in the work area.

Risk of injury in head and eyes

• Always, when operating pneumatic equipment wear 

protection glasses in compliance with the AMSI Z887.1 

Standard.  As additional protection, wear a mask.

• Never aim the air flow towards people or animals.

• Disconnect the air hose from the tool when not in use.

• Never set a tool unattended when connected to the air 

outlet.

• Before using the tool verify all the parts and accessories 

are perfectly secured.

To prevent head and eyes injuries

   

         • Abrasive tools like grinders, sanders 

and cutting tools generate dust and particles that damage 

the lungs and respiratory system.

• Some materials like resin or adhesive are made with 

chemicals and the vapors emitted may cause serious 

damage if the operator is exposed for long periods of time.

Risk of inhaling particles

• Always wear a face mask or breathing device when 

operating these types of tools.

• Always work in a clean, well ventilated area.

To prevent inhaling particles

   

         • Pneumatic tools do not have electric 

insulation.  If during the operation, the tool makes contact 

with a source of electricity, the energy will be conducted to 

the operator causing a fatal electrocution.

Risk of electric shock

• Never use pneumatic tools to work energized electric 

wiring.

• Before operating the tool find the possible hidden wiring 

in the work zone to prevent making contact.

• Avoid contact with grounded surfaces like pipes, 

radiators o refrigerators. The risk of electrocution 

increases if the operator’s body gets grounded.

To prevent electric shock

   

         • Incorrect handling of pressure in 

pneumatic equipment may cause an explosion causing 

severe injuries.

Risk of explosion

• Before using the tool double check the compressed air 

source is regulated to the tool specified pressure and 

must not exceed 1 380 kPa (200 PSI).

To prevent explosions

   

         • Being exposed long periods of time to 

noise pneumatic tools produce may damage hearing 

permanently causing hearing loss.

Risk of hearing loss

• Always, when operating pneumatic equipment

wear hearing protection in compliance with the

ANSI S3.19 Standard

To prevent hearing loss

   

         • Pneumatic tools forced beyond the 

capacity and lacking of adequate lubrication or used to 

loosen rusted nuts (with impact guns) will get damaged 

and make the Warranty void.

Risk of damaging the tool

• Keep the tool duly lubricated.

• Do not force the tool.

• Apply “loose it all” liquid to rusted nuts or lugs before 

trying to loosen with the tool (impact gun).

To prevent damaging the tool

CAUTION

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

ENGLISH

Содержание 19368

Страница 1: ...rsible Air Drill TPN 788RX Model TPN 788RX Code 19368 Applies for Chuck 3 8 Use oil continuously and dosed to lubricate the tool WARNING CAUTION Read this manual thoroughly before using the tool ENGLI...

Страница 2: ...l prolong the duty life make the Warranty valid if necessary and to avoid hazards of fatal injuries please read and understand this Manual before using the tool ENGLISH Technical data Filtering and lu...

Страница 3: ...and the connectors shall be 1 4 NPT Use the right size and good quality couplers and accessories CAUTION Dust water and lack of oil specific for pneumatic tools are the main cause of potential flaws...

Страница 4: ...severe personal injuries or crushing Wear adequate protective safety accessories Wear eye protection dust mask non skid safety shoes helmet and ear plugs In normal conditions the risk of injury is red...

Страница 5: ...s Pneumatic tools do not have electric insulation If during the operation the tool makes contact with a source of electricity the energy will be conducted to the operator causing a fatal electrocution...

Страница 6: ...rp or abrasive edges Unplug the hose when setting up accessories like grinding discs or bits Never use the hose to carry the tool Never pull the hose to unplug it Do not expose the hose to heat oil or...

Страница 7: ...ir Intake Adapter Air Hose Plastic Cap Air intake connection Remove the plastic cap that covers the air inlet at the base of the handle Connect the air hose to the tool using an adapter not included b...

Страница 8: ...ic tools need constant lubrication along their useful life and during the operation The compressed air needed in the tool to run carry humidity which could oxidize the motor and bearing in the tool To...

Страница 9: ...O ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULAN...

Страница 10: ...t the product in Corregidora 22 Col Centro Alc Cuauht moc CDMX C P 06060 or at the establishment where you purchased it or at any Truper Service Center listed in the annex to the warranty policy and o...

Страница 11: ...esentar el producto en Corregidora 22 Col Centro Alc Cuauht moc CDMX C P 06060 o en el establecimiento donde lo compr o en alg n Centro de Servicio Truper de los enlistados en el anexo de la p liza de...

Страница 12: ...RO DE SERVICIO ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C...

Страница 13: ...echo a realizar mejoras t cnicas sin previo aviso Despu s de cada 60 horas de operaci n el mecanismo de la herramienta se deber engrasar un poco El exceso de grasa puede disminuir la potencia Puesta e...

Страница 14: ...e aire Adaptador Manguera de aire Tap n pl stico Conexi n de la toma de aire Retire el tap n pl stico que cubre la entrada de aire en la base del mango Conecte la manguera de aire a la herramienta por...

Страница 15: ...ejada se superficies afiladas o abrasivas Desconecte la manguera cuando instale accesorios como discos de esmeril o brocas Nunca use la manguera para cargar la herramienta Nunca jale de la manguera pa...

Страница 16: ...eraci n llegan a hacer contacto con alguna fuente de electricidad conducir la energ a al operador provocando electrocuci n incluso fatal Riesgo de choque el ctrico Jam s utilice herramientas neum tica...

Страница 17: ...e protecci n personal Utilice protecci n para los ojos Mascarilla antipolvo zapatos de seguridad antideslizantes casco y protecci n para los o dos en condiciones adecuadas reducen considerablemente el...

Страница 18: ...esi n de l nea o el di metro interior de la manguera para compensar el uso de mangueras muy largas m s de 8 metros El di metro interior m nimo de la manguera debe ser de 3 8 9 5 mm y los conectores de...

Страница 19: ...rant a en caso de ser necesario y evitar riesgos o lesiones graves es fundamental leer este Instructivo por completo antes de usar la herramienta ATENCI N ESPA OL Especificaciones t cnicas Requerimien...

Страница 20: ...X Modelo TPN 788RX C digo 19368 Este Instructivo es para 9 5 mm Broquero 3 8 Utilice aceite de forma continua y dosificada para lubricar la herramienta ADVERTENCIA ATENCI N Lea este Instructivo por co...

Отзывы: