background image

3

12780

12781

12782

5 A

8 A

11 A

98 ft

180 ft

196 ft

10,5 gal/min

15,8 gal/min

11,8 gal/min

1/2 Hp

3/4 Hp

1 Hp

60 Hz

Self-priming peripheral water pump

Code

Description

Voltage

Frequency

3450 RPM

Speed

Current

Power

Power Cord Grips used in this product: Type “Y”.

Tool Build Quality: Basic insulation

Thermal insulation on motor winding: Class F

127 V

1” -11,5 NPT

Outlet and Inlet Diameter

Total Manometric Maximum

Height Value / Maximum Height

50 minutes’ work per 20 min rest. Maximum 6 hours’ daily

18 AWG

16 AWG

Conductors

Work Cycle

Class I

Insulation

IPX4

Grade IP

26 ft

Maximum Suction Depth

Maximum Water Temperature

104 °F

Maximum Flow

BOPA-1/2

BOPA-1

BOPA-3/4

                          A professional electrician shall carry out the 

connection to the power source following the electric diagram to 

the right.

                          Use a separate electric circuit for the pump.  

This circuit shall not have a conductor with a gauge lower to #12 

and shall be protected with a 20 A time-delay fuse.  Before you 

connect the motor to the power line. double check the switch is 

in the OFF position and the electric current is equal to the one 

indicated in the motor nameplate.  If the pump is operated with 

lower voltage, the motor will get damaged.

                             All wiring, electric connections and the system

ground connection shall comply with the 

NORMA OFICIAL 

MEXICANA NOM-001-SEDE, INSTALACIONES ELÉCTRICAS 

(UTILIZACIÓN)

 or with the local codes and ordinances. Call a certified electrician. It is advisable the pump shall 

feed with a circuit that includes a differential circuit breaker with an assigned current to higher than 30 mA

CAUTION

CAUTION

Switch

127 V~

127 V~

Fuse

Pressure

switch

Motor

Connections

Motor

Connections

Thermal

connection

WARNING

Technical Data

Power Requirements

ENGLISH

WARNING

WARNING

Avoid the risk of electric shock or severe injury. When the power cable gets damaged 

it should only be replaced by the manufacturer or at a                                 Authorized Service Center.

The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.

Do not expose to rain, liquids and/or dampness.

Before gaining access to the terminals all power sources should be disconnected.

Содержание 12780

Страница 1: ...g Peripheral Water Pump BOPA 1 2 BOPA 3 4 BOPA 1 Models Codes BOPA 1 2 BOPA 3 4 BOPA 1 Applies for 12780 12781 12782 For agriculture CAUTION ENGLISH ESPA OL Read the user s manual thoroughly before op...

Страница 2: ...3 3 4 5 5 6 7 8 9 10 11 12 BOPA 1 2 BOPA 3 4 BOPA 1 Contents ENGLISH CAUTION Keep this manual for future references The illustrations in this manual are for reference only They might be different from...

Страница 3: ...motor to the power line double check the switch is in the OFF position and the electric current is equal to the one indicated in the motor nameplate If the pump is operated with lower voltage the moto...

Страница 4: ...tions Dress properly Do not wear loose clothing or jewelry Keep hair clothes and gloves away from the moving parts Loose clothes or long hair may get caught in moving parts If you have dust extraction...

Страница 5: ...WARNING WARNING The pump is a stationary device designed to pump clean neutral liquids with no abrasive solids suspended in temperatures not above 104 F It is useful for orchards to pump non aggressiv...

Страница 6: ...eight exceeds 13 ft or the distance between the pump and the water inlet is 33 ft use a pipe with a bigger diameter The suction pipe shall be watertight It shall be submerged in water at least 1 5 ft...

Страница 7: ...according to the electric diagram in page 3 or in the pump nameplate The pump is built with a one phase motor protected against overcharge using a thermal device overcurrent cut set in the winding El...

Страница 8: ...the foot valve not included regularly and clean it if necessary If the pump is not being used for long periods of time it is advisable to empty the pump rinse with clean water and store it in a dry p...

Страница 9: ...pe length Clean the foot valve and the whole suction pipe if necessary Check voltage and ventilation Release it with a screwdriver see page 8 The motor does not start The motor is turning but it is no...

Страница 10: ...10 ENGLISH Notes...

Страница 11: ...NTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULANCINGO HGO TEL 775 753 6615 775 753 6616 SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO D...

Страница 12: ...d by personnel not authorized by In order to make the warranty valid or to purchase components and spare parts you must present the product and its proof of purchase at Av San Isidro 110 Col Industria...

Страница 13: ...rizado por Para hacer v lida la garant a o adquirir piezas y componentes deber presentar el producto y su comprobante de compra en Av San Isidro 110 Col Industrial San Antonio Alc Azcapotzalco C P 027...

Страница 14: ...C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULANCINGO HGO TEL 775 753 6615 775 753 6616 SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 4...

Страница 15: ...10 Notas ESPA OL...

Страница 16: ...minuya la longitud del tubo de succi n Limpie la v lvula de pi y todo el tubo de succi n de ser necesario Revise la tensi n y la ventilaci n Lib relo con un desarmador consulte la p gina 8 El motor no...

Страница 17: ...uevo Revise peri dicamente la v lvula de pie no incluida y l mpiela si es necesario Si la bomba permanecer inactiva por un largo periodo es recomendable vaciarla por completo enjuagarla con agua limpi...

Страница 18: ...necte las fases de acuerdo al diagrama el ctrico de la p gina 3 o de la placa de la bomba La bomba tiene un motor monof sico protegido contra sobrecargas usando un dispositivo t rmico corte de sobreco...

Страница 19: ...o la distancia entre la bomba y la toma de agua es de 10 m use un tubo con un di metro m s grande El tubo de succi n debe de ser completamente herm tico debe de estar sumergido en el agua por lo meno...

Страница 20: ...nario dise ado para bombear l quidos neutros limpios que no tengan s lidos abrasivos en suspensi n a temperaturas no superiores a 40 C til para riegos de huertas para bombear l quidos no agresivos y p...

Страница 21: ...nes inesperadas Vista adecuadamente No vista ropa suelta o joyas Mantenga su pelo su ropa y guantes alejados de las piezas en movimiento La ropa o el pelo sueltos o las joyas pueden quedar atrapados e...

Страница 22: ...ximo 6 h diarias 18 AWG 16 AWG Conductores Ciclo de trabajo Clase I Aislamiento IPX4 Grado IP 8 m M xima profundidad de succi n Temperatura m xima del agua 40 C Flujo m ximo BOPA 1 2 BOPA 1 BOPA 3 4...

Страница 23: ...zados P liza de Garant a Guarde este instructivo para futuras referencias Los gr ficos de este instructivo son para referencia pueden variar del aspecto real de la herramienta 3 3 4 5 5 6 7 8 9 10 11...

Страница 24: ...rica autocebante BOPA 1 2 BOPA 3 4 BOPA 1 Modelos C digos BOPA 1 2 BOPA 3 4 BOPA 1 Este instructivo es para 12780 12781 12782 Uso agr cola ESPA OL ENGLISH ATENCI N Lea este Instructivo por completo an...