IP Grade
IP20
Class II
CM-14N
Technical Data
Power Requirements
11723
14”
120 V˜
60 Hz
Chop saw
14 AWG x 2C with insulating temperature of 167 °F
3 900 RPM
3 Hp
15 A
Code
Description
Disc Diameter
Voltage
Frequency
Current
Power
Speed
50 minutes work per 20 minutes idle. Maximum 6 hours per day.
Duty Cycle
Conductors
Insulating
Power Cord Grips used in this product: Type “Y”.
Tool Build Quality: Double Insulation
Thermal insulation on motor winding: Class E
3
ENGLISH
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
Tools with double insulation are equipped with a polarized plug
(one prong is wider than the other). This plug will only fit in the right way into a
polarized outlet. If the plug cannot be introduced into the outlet, reverse the plug. If
it still doesn’t fit, call a qualified electrician to install for you a polarized outlet. Do
not alter the plug in any way. Double insulation eliminates the need of a grounded
third power cord with three prongs or a grounded power connection.
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cable’s length and the ampere capability shown in
the tool’s nameplate. When in doubt use the next higher gauge.
WARNING
WARNING
WARNING
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
18 AWG(*)
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
from 5.9’ to 49.2’ | higher than 49.2’
Ampere
Capacity
Number of
Conductors
Extension gauge
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
When operating power tools outdoors, use a grounded
extension cable labeled “For Outdoors Use”. These extensions are specially designed
for operating outdoors and reduce the risk of electric shock.