![Truma Ultraheat S 3004 P Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/truma/ultraheat-s-3004-p/ultraheat-s-3004-p_installation-instructions-manual_1176046006.webp)
6
Installation instructions
The unit must only be installed and repaired by an
expert.
Read the installation instructions carefully before
working, and then comply with them!
Disregarding safety instructions or erroneous in-
stallation can put people in danger and cause
damage to property.
Intended use
The Ultraheat additional electric heater is suitable for installa-
tion in an S 3004, S 3004 P, S 5004 or S 5004 E (NL) heater.
The additional heater is attached to the installation box of the
heater and sits between the installation box and the heat ex-
changer. An electrical connection with 230 V ~ 50 Hz (8.5 A)
is required to operate the additional heater.
Other applications are only permitted after prior consultation
with Truma.
Declaration of conformity
The Ultraheat additional electric heater has been tested by
the DVGW and is entitled to bear the CE mark. (Declaration of
conformity – see operating instructions of relevant heater)
The CE product identification number of the heater remains
valid.
Regulations
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
– Modifications to the device (including accessories)
– Modifications to the exhaust duct and the cowl
– Failure to use original Truma parts as replacement parts and
accessories
– Failure to follow the installation and operating instructions
This may also invalidate the device operating permit, which in
many countries also denotes cancellation of the vehicle oper-
ating permit.
Retrofitting
Retrofitting an Ultraheat additional electric heater requires re-
moval of the heater including the installation box and the fan,
and may only be carried out by an expert.
After removal, the additional heater is installed in the installa-
tion box as described under “Initial installation”.
It is essential to fit a new O-ring (34) before re-connect-
ing the exhaust pipe.
34
Fig. 1
Initial installation
S 3004, S 3004 P
Break through pre-punched opening (U) in the installa-
tion box (1) for leading through the control electrics.
Insert heating element (70) from the inside of the installation
box (1) and secure with six B 3.5 x 9.5 mm screws.
Install the installation box (1) and the TEB-3 or TN-3 fan as
described in the installation instructions for the heater.
1
70
3 x (3.5 x 12)
6 x (3.5 x 9.5)
U
Fig. 2
Perform remainder of heater installation as per the installation
instructions for the relevant heater.
S 5004, S 5004 E (NL)
Break through pre-punched opening (U) on the outer
part of the installation box (1) for leading through the
control electrics.
Break off the lower part of the installation box inner section (2)
at the perforation (2a).
Insert heating element (70) from the inside of the installation
box outer section (1) and secure with six B 3.5 x 9.5 mm
screws.
Install outer (1) and inner (2) parts of installation box and in-
stall TEB-3 or TN-3 fan as described in the heater installation
instructions.
1
2
2a
3 x (3.5 x 12)
6 x (3.5 x 9.5)
70
U
Fig. 3
Perform remainder of heater installation as per the installation
instructions for the relevant heater.
Содержание Ultraheat S 3004 P