Truma DuoComfort Скачать руководство пользователя страница 5

5

If necessary, use the control knob 
(a) to manually select which cyl-
inder will be operating and which 
will be held in reserve. 

Always turn control knob (a) as far 
to the left or right as it will go (an 
intermediate position will cause 
gas to be removed from both 
gas cylinders simultaneously).

Removal status

In the normal position (operating 
cylinder on the left, reserve cyl-
inder on the right), the following 
display will be seen:

 

– Status display (b) is green = 

gas taken from the left cylin-
der (operating cylinder).

 

– Status display (b) is red = gas 

taken from the right cylinder 
(reserve cylinder).

Changing cylinders

Residual gas: No smok-
ing, no naked flames!

 DuoComfort offers the possibility 
of changing empty gas cylinders 
without interrupting operation 
of the consumers. Non-return 
valves integrated into the inlet 
connections prevent gas from 
escaping when only one gas 
cylinder is attached for a short 
time (see “Using only one gas 
cylinder”).

 

– Rotate the control knob (a) by 

180° or half a turn to the stop 
position, and the previous 
reserve cylinder becomes the 
operating cylinder. After the 
cylinder change the full gas 
cylinder is available again as 
the reserve cylinder.

  The status display (b) changes 

to green.

 

– Close the empty cylinder's 

valve and screw off the high 
pressure hose.

 

– Screw the high-pressure hose 

onto the full gas cylinder and 
open the cylinder valve. If 
necessary firmly press the 
hose rupture protection (d) for 
about 5 seconds. 

The status display (b) remains 
on green.

After any intervention, 
check the hose connection 

on the cylinder valve for leaks 
(see “Checking for leaks in the 
high-pressure section”).

Содержание DuoComfort

Страница 1: ...Operating instructions Page 2 To be kept in the vehicle DuoComfort ...

Страница 2: ... one gas cylinder 6 Checking for leaks in the high pressure section 6 Accessories 7 Technical data 7 Symbols used The unit may only be installed and repaired by an expert Symbol indicates possible hazards Note containing infor mation and tips Intended use Truma DuoComfort is an auto matic changeover valve for a two cylinder system It permits replacement of gas cylinders without interrupting the ga...

Страница 3: ...as equip ment and gas systems Gas cylinders from which gas is taken in the liquid phase e g for fork lifts must not be used since they would result in damage to the gas system Two high pressure hoses are needed for connecting to the gas cylinders Truma provides the necessary high pressure hoses with the most common ly used connection variants for European gas cylinders see Page 67 68 High pressure...

Страница 4: ...ions are in good condition Open the valves on both gas cylinders Firmly press the hose rupture protection d green button for about 5 seconds The dis play in the mica window b turns green Operating instructions Put the gas pressure regu lation system into operation see the relevant operating instructions Changeover As soon as the pressure in the operating cylinder falls below 0 5 bar the valve auto...

Страница 5: ... cylinders without interrupting operation of the consumers Non return valves integrated into the inlet connections prevent gas from escaping when only one gas cylinder is attached for a short time see Using only one gas cylinder Rotate the control knob a by 180 or half a turn to the stop position and the previous reserve cylinder becomes the operating cylinder After the cylinder change the full ga...

Страница 6: ...anging the hose ensure that the seal pro vided with the hose hose outlet changeover valve inlet is correct ly installed and is not damaged We recommend that the seal part no 50020 76300 be replaced every time the hose is changed After any intervention check the hose connection on the cylinder valve and at the DuoComfort inlet for leaks see Checking for leaks in the high pressure section Using only...

Страница 7: ...shows the removal status from inside the vehicle part no 50211 01 Elbow union 90 part no 50020 56000 Additional kit required when gas cylinders are more than 100 cm apart part no 50020 61100 Gas remote switch for shutting off the gas supply from the vehicle interior GS 8 part no 57014 01 GS 10 part no 57024 01 Screw aid part no 50020 61500 Gas filter suitable for all wall mounted changeover valves...

Страница 8: ... Union nut M20 x 1 5 H 20 Recommended tightening torque 3 5 Nm for union nut M20 x 1 5 G 13 H 20 Operating temperature 20 C to 50 C Product ID number CE 0085BQ0102 DG approval number 3894 Subject to technical changes ...

Страница 9: ...0 06 50420 06 o butane propane G 10 50410 05 50420 05 G 12 50410 01 50420 01 o Gängigster Anschluss Most common connection Raccordement le plus courant o Ebenfalls erhältliche Anschlüsse Also available connections Raccordements également disponibles x für Gasflaschen mit Clip on Adapter for gas cylinders with clip on adapter pour bouteilles de gaz avec adaptateur à clipser Art Nr part no N d art 5...

Страница 10: ...0410 06 50420 06 o x G 10 50410 05 50420 05 G 12 50410 01 50420 01 o Gängigster Anschluss Most common connection Raccordement le plus courant o Ebenfalls erhältliche Anschlüsse Also available connections Raccordements également disponibles x für Gasflaschen mit Clip on Adapter for gas cylinders with clip on adapter pour bouteilles de gaz avec adaptateur à clipser Art Nr part no N d art 50410 xx 45...

Страница 11: ...ς και τοποθέτησης στη γλώσσα της χώρας σας από τον κατασκευαστή Truma ή από το σέρβις της Truma στη χώρα σας Návod k použití a montáži si lze v jazyce vaší země vyžádat u výrobce Truma nebo servisu Truma ve vaší zemi Návod na použitie a montáž vo Vašom štátnom jazyku si môžete vyžiadať u výrobcu Truma alebo v servise Truma vo Vašej krajine Instrukcję obsługi i montażu we właściwej wersji językowej...

Отзывы: