Truma DuoComfort Скачать руководство пользователя страница 4

4

Control and display panels

DuoComfort

min. 

50 cm

a

d

d

b

c

Figure 1 

– MonoControl CS 

example

a  =  control knob for the oper-

ating / reserve cylinder

b  =  status display – operating / 

reserve cylinder (green / red) 

c  =  green reset button – crash 

sensor triggering element

d  =  green button – hose rupture 

protection

 Truma offers a remote in-
dicator as an accessory 

(part no. 50210-01) to permit 
reading of the operating cylin-
der's status from inside the 
vehicle.

Start-up

 

– For example, turn control knob 

(a) to the left until it stops 
(left connection is operating 
cylinder.

 

– Connect gas cylinders and 

make sure all hose connec-
tions are in good condition.

 

– Open the valves on both gas 

cylinders.

 

– Firmly press the hose rupture 

protection (d – green button) 
for about 5 seconds. The dis-
play in the mica window (b)
turns green.

Operating instructions

 

– Put the gas pressure regu-

lation system into operation 
(see the relevant operating 
instructions).

Changeover

As soon as the pressure in the 
operating cylinder falls below 
0.5 bar, the valve automatically 
switches over and begins taking 
gas from the second gas cylin-
der. The display in the mica win-
dow turns red.

In extreme cold or when a 
large amount of gas is con-

sumed from the cylinder over a 
long period of time, the gas pres-
sure may fall below 0.5 bar even 
though there is still some gas left 
in the cylinder. This may result in 
gas being taken from both gas 
cylinders simultaneously.

Содержание DuoComfort

Страница 1: ...Operating instructions Page 2 To be kept in the vehicle DuoComfort ...

Страница 2: ... one gas cylinder 6 Checking for leaks in the high pressure section 6 Accessories 7 Technical data 7 Symbols used The unit may only be installed and repaired by an expert Symbol indicates possible hazards Note containing infor mation and tips Intended use Truma DuoComfort is an auto matic changeover valve for a two cylinder system It permits replacement of gas cylinders without interrupting the ga...

Страница 3: ...as equip ment and gas systems Gas cylinders from which gas is taken in the liquid phase e g for fork lifts must not be used since they would result in damage to the gas system Two high pressure hoses are needed for connecting to the gas cylinders Truma provides the necessary high pressure hoses with the most common ly used connection variants for European gas cylinders see Page 67 68 High pressure...

Страница 4: ...ions are in good condition Open the valves on both gas cylinders Firmly press the hose rupture protection d green button for about 5 seconds The dis play in the mica window b turns green Operating instructions Put the gas pressure regu lation system into operation see the relevant operating instructions Changeover As soon as the pressure in the operating cylinder falls below 0 5 bar the valve auto...

Страница 5: ... cylinders without interrupting operation of the consumers Non return valves integrated into the inlet connections prevent gas from escaping when only one gas cylinder is attached for a short time see Using only one gas cylinder Rotate the control knob a by 180 or half a turn to the stop position and the previous reserve cylinder becomes the operating cylinder After the cylinder change the full ga...

Страница 6: ...anging the hose ensure that the seal pro vided with the hose hose outlet changeover valve inlet is correct ly installed and is not damaged We recommend that the seal part no 50020 76300 be replaced every time the hose is changed After any intervention check the hose connection on the cylinder valve and at the DuoComfort inlet for leaks see Checking for leaks in the high pressure section Using only...

Страница 7: ...shows the removal status from inside the vehicle part no 50211 01 Elbow union 90 part no 50020 56000 Additional kit required when gas cylinders are more than 100 cm apart part no 50020 61100 Gas remote switch for shutting off the gas supply from the vehicle interior GS 8 part no 57014 01 GS 10 part no 57024 01 Screw aid part no 50020 61500 Gas filter suitable for all wall mounted changeover valves...

Страница 8: ... Union nut M20 x 1 5 H 20 Recommended tightening torque 3 5 Nm for union nut M20 x 1 5 G 13 H 20 Operating temperature 20 C to 50 C Product ID number CE 0085BQ0102 DG approval number 3894 Subject to technical changes ...

Страница 9: ...0 06 50420 06 o butane propane G 10 50410 05 50420 05 G 12 50410 01 50420 01 o Gängigster Anschluss Most common connection Raccordement le plus courant o Ebenfalls erhältliche Anschlüsse Also available connections Raccordements également disponibles x für Gasflaschen mit Clip on Adapter for gas cylinders with clip on adapter pour bouteilles de gaz avec adaptateur à clipser Art Nr part no N d art 5...

Страница 10: ...0410 06 50420 06 o x G 10 50410 05 50420 05 G 12 50410 01 50420 01 o Gängigster Anschluss Most common connection Raccordement le plus courant o Ebenfalls erhältliche Anschlüsse Also available connections Raccordements également disponibles x für Gasflaschen mit Clip on Adapter for gas cylinders with clip on adapter pour bouteilles de gaz avec adaptateur à clipser Art Nr part no N d art 50410 xx 45...

Страница 11: ...ς και τοποθέτησης στη γλώσσα της χώρας σας από τον κατασκευαστή Truma ή από το σέρβις της Truma στη χώρα σας Návod k použití a montáži si lze v jazyce vaší země vyžádat u výrobce Truma nebo servisu Truma ve vaší zemi Návod na použitie a montáž vo Vašom štátnom jazyku si môžete vyžiadať u výrobcu Truma alebo v servise Truma vo Vašej krajine Instrukcję obsługi i montażu we właściwej wersji językowej...

Отзывы: